Connect the hydraulic hoses (1) to the plug-in connections provided for this purpose on the
forage harvester.
•
Close the dust caps (2)
Pos: 43 /BA/Inbetriebnahme/Vorsätze/Ankuppeln/Ankuppeln Bild T3 EASYFLOW 300 @ 67\mod_1302675541005_78.docx @ 619277 @ @ 1
1
1
EFL000010
2
2
I
II
Fig. 9
Pos: 44 /BA/Inbetriebnahme/Vorsätze/Ankuppeln/Ankuppeln T3 Text EASYFLOW 300 @ 67\mod_1302761198691_78.docx @ 620623 @ @ 1
•
Unlock the pendulum frame, move the locking pin (1) from position I (locked) to position II
(unlocked) and secure with spring cotter pin (2)
•
On both sides swivel the socket pins (3) of the parking supports (4) 180° upwards and pull
them out
•
Push parking supports (4) upwards and secure them in the bore (5) with socket pin (3).
Lock socket pin (3) by turning it 180° downwards