Terminal menus
13
Menu 9 “Filling correction” 13.15
Comprima V 180
Original Operating Instructions 150001053_00_en
123
The following modes can be selected:
Icon
Explanation
Net wrapping
Chamber film wrapping
13.15
Menu 9 “Filling correction”
If the bale diameter is not reached or is too high, the filling correction can be used to correct the
bale diameter within a pre-defined range (bale size -10 to +10 cm).
n
+
-
10
-10
0
cm
+
-
9
EQG003-018
ü
For The menu level is active,
.
To open the menu, press
+
-
.
Æ
The display shows menu “Filling correction”.
Adjusting the filling correction
Increase or decrease the value,
.
To save the value, press
.
Example
The set target bale diameter is 108 cm.
If the actual bale diameter is only 100 cm and thus 8 cm too small, a correction value of + 8 cm
must be set.
This means:
Correction value=target bale diameter - bale diameter