Maintenance
6.13.4
Compressed air reciever
The compressed air receiver stores the compressed air
supplied by the compressor. During operation, therefore,
condensation water may collect in the receiver.
The compressed air filter must be regularly emptied:
– every day during winter (when used),
– otherwise, every week but
– at least after 20 operating hours.
The receiver is drained via the drainage valve on the
underside.
• Shut down the feeder wagon and secure.
• Open the drain valve and release the condensation
water.
• Check the drain valve, clean it and screw it back in.
A heavily contaminated or leaky drain
valve must be replace with a new one.
6.14 Care after daily use
After daily operation, the area of the conveyor and
cutter unit as well as the area next to it must be
cleaned and regularly treated with preservatives.