Krom Schroder VGP10 Operating Instructions Manual Download Page 6

GB-6

D

GB

F

NL

I

E

 27 

 Tightness OK: the unit is ready for operation.

 28 

 Open the pipeline again and release the gas 

supply.

Assistance in the event of 
malfunction

 WARNING

Electric shocks can be fatal! Before working on 
possible live components, ensure the unit is discon-
nected from the power supply.
Fault-clearance must only be undertaken by author-
ized trained personnel.
Unauthorized repairs or incorrect electrical con-
nections can cause the solenoid valve to become 
defective. In this case, our warranty will be ren-
dered void. 

  ?  

 

Fault

  !  

 

Cause

 • 

 

Remedy

Possible faults and suggested solutions
  ?  

 

The solenoid valve does not open, there is 
no flow downstream of the solenoid valve.

 ! 

 There is no power supply.

 • 

 Check wiring, see page 3 (Wiring).

  !  

 Rectifier adapter defective.

 • 

 Remove socket and rectifier adapter, see 

page  4 (Replacing the actuator), steps 

  

 

to 

 5 

. Check the ohmic resistance of the rectifier 

adapter between contacts 

 and 

2

. Note the 

inscription on the rectifier adapter.

 • 

 No resistance, replace adapter. 

 • 

 The rectifier adapter is available separately as a 

spare part.

 ! 

 Actuator defective.

 • 

 Remove socket and rectifier adapter, see 

page  4 (Replacing the actuator), steps 

  

 

to 

 5 

. Check the ohmic resistance of the actuator 

between contacts 

 (N) and 

2

 (L). Read off the 

contact assignment from the rectifier adapter.

 • 

 No resistance, change actuator, see page 

(Replacing the actuator).

 • 

  The actuator set is available separately as a spare 

part.

 ! 

  Guiding elements bent. Incorrect handling when 

installing the unit.

 • 

 Dismantle the unit and return it to the manufac-

turer.

  ?  

 

The solenoid valve does not close securely, 
the flow downstream of the solenoid valve 
does not stop.

  !  

 Valve seat is dirty.

 • 

 Clean the valve seat, see page  4 (Mainte-

nance).

 • 

 Install a filter upstream of the solenoid valve.

 ! 

 Valve seat is damaged.

 • 

 Dismantle the unit and return it to the manufac-

turer.

 ! 

 Valve seal is damaged or hardened.

 • 

 Replace the valve seal, see page 4 (Mainte-

nance).

  !  

  Guiding elements bent. Incorrect handling when 

installing the unit.

 • 

 Dismantle the unit and return it to the manufac-

turer.

Summary of Contents for VGP10

Page 1: ...WARNING Indicates possible danger to life and limb CAUTION Indicates possible material damage All interventions may only be carried out by qualified gas technicians Electrical interventions may only b...

Page 2: ...D 49018 Osnabr ck Germany VGP Installation CAUTION Please observe the following to ensure that the VGP is not damaged during installation and operation Do not clamp the unit in a vice Only secure the...

Page 3: ...n be rotated 2 1 3 1 N 2 L 4 5 3 6 7 8 Plug insert can be rotated in 90 steps 10 9 12 11 Tightness test CAUTION Please observe the following to ensure that the VGP is not damaged during the tightness...

Page 4: ...year or every six months if operated with biogas Checking tightness and function In order to determine whether the VGP is tight and closes securely check the internal and ex ternal tightness see page...

Page 5: ...observe the following to ensure that the VGP is not damaged during subsequent operation Install the closing spring in the correct position Ensure that the catch of the closing spring is positioned in...

Page 6: ...Note the inscription on the rectifier adapter 1 2 No resistance replace adapter The rectifier adapter is available separately as a spare part Actuator defective Remove socket and rectifier adapter see...

Page 7: ...based on using the product in accordance with these operating instructions Once the designed lifetime has been reached safety relevant products must be replaced Designed lifetime based on date of man...

Page 8: ...equirements of the listed Direc tives and Standards Directives 2009 142 EC GAD valid until 20 April 2018 2014 30 EU 2014 35 EU Regulation EU 2016 426 GAR valid from 21 April 2018 The relevant product...

Reviews: