dimension
a
[min.]
b
[min.]
c
20 mm 50 mm 20 mm
For an optimal combustion inside a
boiler, we recommend to insert a glow
pipe or mat.
Herewith we generate a hot burning
chamber
advantages:
-
Energie saving
-
better combustion
-
longer lifetime of the burner
Mounting:
Insert the glow pipe inside the burning
chamber, thereby the minimum dimensions mentioned
above have to be observed. The flame must be in the
middle of the glow pipe, therefor you must eventually base
the glow pipe with adequate, fire resistent material.
Insertion:
is recommended in cast iron boilers, where sometimes several flues are lead
out of the burning chamber.
The ceramic fibre board must cover the burning chamber bottom completely and
laterally be placed as high as possible. Pay attention, that the flues are not
covered.
ceramic fibre board
Ceramic fibre board
Glow pipe mounting
Glow pipe installation