3
INSTALLATION
32
OPTISWIRL 4200
www.krohne.com
02/2022 - 4003930810 - MA OPTISWIRL4200 R10 en
3.4.5 Preferred mounting position for device with pressure sensor
Figure 3-8: Preferred mounting position for device with pressure sensor
1
Above a horizontal pipe
2
Underneath a horizontal pipe (not permitted with lines at risk of condensate forming)
3
On a vertical pipe
4
Horizontal pipeline with signal converter orientation of 90° to side with pressure sensor syphon orientation downwards
5
Not recommended:
Horizontal pipeline with signal converter orientation of 90° to side with pressure sensor syphon orientation upwards
INFORMATION!
Depending on the installation position, you may have to rotate the display and/or the connection
housing.