2.7.2  With electronics P (Profibus PA), F (Foundation Fieldbus)

The metallic parts of OPTIBAR DP 7060 VGK7*A/W/V E/Z/6/7 are electrically connected with the 
ground terminals.

The supply and signal circuit is reliably isolated from parts which can be grounded by a galvanic 
isolation.

2.7.3  With separate cable outlet

The metallic parts of OPTIBAR DP 7060 VGK7*A/W/V E/Z/6/7 are electrically connected with the 
ground terminals.

The supply and signal circuit is reliably isolated from parts which can be grounded by a galvanic 
isolation.

OPTIBAR DP 7060 VGK7*A/W/V E/Z/6/7 with electronics P (Profibus PA), F (Foundation 
Fieldbus), version with single chamber housing A, V

Supply and signal circuit:

(Terminals 1[+], 2[-] in electronic 

compartment)

Indicating and adjustment circuits: 

(terminals 5, 6, 7, 8)

U

i

 = 9...32 VDC

U

m

 = 253 VAC

Circuit for the display and adjustment 

module: (spring contacts in the 

electronic compartment)

For connection to the display and adjustment module.

OPTIBAR DP 7060 VGK7*A/W/V E/Z/6/7 with electronics P (Profibus PA), F (Foundation 
Fieldbus), version with double chamber housing D, W

Supply and signal circuit:

(Terminals 1[+], 2[-] in terminal 

compartment

Indicating and adjustment circuits: 

(terminals 5, 6, 7, 8)

U

i

 = 9...32 VDC

U

m

 = 253 VAC

Circuit for the display and adjustment 

module: (spring contacts in the 

electronic compartment)

For connection to the display and adjustment module.

OPTIBAR DP 7060 VGK7*A/W/V E/Z/6/7 version with separate cable outlet 
(all electronics)

Circuit between sensor and external 

electronics

(terminal 1 - yellow, 

terminal 2 - white, terminal 3 - red, 

terminal 4 - black)

in protection type intrinsic safety Ex ia IIC

For the OPTIBAR DP 7060 VGK7*A/W/V E in the version with 

the permanently mounted cable to the measuring sensor unit 

and external electronics, the length of the supplied cable 

between the external housing and the measuring sensor unit 

should not exceed 180 m.

Summary of Contents for OPTIBAR DP 7060

Page 1: ...uminium Single chamber double chamber Stainless steel precision casting Single chamber double chamber OPTIBAR DP 7060 OPTIBAR DP 7060 OPTIBAR DP 7060 OPTIBAR DP 7060 Supplementary Instructions Supplem...

Page 2: ...With electronics Z 4 20 mA H 4 20 mA HART A 4 20 mA HART with SIL qualifica tion 10 2 7 2 With electronics P Profibus PA F Foundation Fieldbus 11 2 7 3 With separate cable outlet 11 3 Installation 12...

Page 3: ...le for use in hazardous atmospheres of all combustible materials of explosion group IIA IIB and IIC for applications requiring category 1 2G or 2G equipment When the OPTIBAR DP 7060 VGK7 A W V E Z 6 7...

Page 4: ...use of the device which have been listed in these instructions If needed the IEC certificate can be downloaded from the manufacturer s website 1 4 Safety instructions Assembly installation start up a...

Page 5: ...ng for ATEX The marking of the entire device is on the housing where the following identification plate can be found Figure 2 1 Example for an ATEX nameplate for a OPTIBAR DP 7060 1 Approvals and Ex d...

Page 6: ...st mixtures no key figures are available for the ignition behaviour Operating conditions Operating conditions Operating conditions Operating conditions Outside of atmospheric conditions the explosion...

Page 7: ...safe circuits d ia according to EN 60079 1 EN 60079 11 and IEC 60079 1 IEC 60079 11 however the device does NOT NOT NOT NOT require an intrinsically safe supply The marking according to ATEX is II 1 2...

Page 8: ...V E Z 6 7 are operated at temperatures higher than those specified in the table above please make sure by means of appropriate measures that there is no danger of ignition from the hot surface The ma...

Page 9: ...0 131 F 40 85 C 40 185 F 1 40 60 C 40 140 F 40 72 C 40 161 6 F 40 85 C 40 185 F 1 40 50 C 40 122 F 40 85 C 40 185 F 40 85 C 40 185 F 1 40 40 C 40 104 F T5 T6 40 46 C 40 114 8 F 40 55 C 40 131 F 1 40 4...

Page 10: ...n with single chamber housing A V Supply and signal circuit Terminals 1 2 in electronic compartment Indicating and adjustment circuits terminals 5 6 7 8 Ui 9 6 35 VDC Um 253 VAC Circuit for the displa...

Page 11: ...i 9 32 VDC Um 253 VAC Circuit for the display and adjustment module spring contacts in the electronic compartment For connection to the display and adjustment module OPTIBAR DP 7060 VGK7 A W V E Z 6 7...

Page 12: ...ervoltage protection in the event of lightning or overvoltage they are not in a pneumatic flow excessive dust deposits over 5 mm and complete dust coverage are prevented there is no danger from mechan...

Page 13: ...re transmitter of the OPTIBAR 7060 series is designed to measure the pressure of vaporous gaseous and liquid media The differential pressure transmitters are supplied as standard with 2 wire 4 20 mA s...

Page 14: ...nstallation of an Ex d cable entry certified according to EN 60079 1 or IEC 60079 1 Simple cable entries should not be used Refer to sections 13 1 and 13 2 of EN 60079 1 or IEC 60079 1 When connecting...

Page 15: ...locking screw of the cover until it stops Unused openings must be sealed according to EN 60079 1 or IEC 60079 1 paragraph 11 9 The cover of the Ex d electronic compartment has the warning label Do no...

Page 16: ...f thread for the Ex d cable entries The Ex d terminal compartment of OPTIBAR DP 7060 VGK7 A W V E Z 6 7 with cable entry type 0 D or 6 has cable entries M20 x 1 5 The Ex d terminal compartment of OPTI...

Page 17: ...device must be removed prior to start up The openings must be closed prior to start up using a method permitted for the protection type Permitted and suitable cable glands or plugs must be installed i...

Page 18: ...5 NOTES 18 OPTIBAR DP 7060 www krohne com 05 2017 4005720001 AD OPTIBAR 7060 Ex db ia R01en...

Page 19: ...NOTES 5 19 OPTIBAR DP 7060 www krohne com 05 2017 4005720001 AD OPTIBAR 7060 Ex db ia R01en...

Page 20: ...ces Head Office KROHNE Messtechnik GmbH Ludwig Krohne Str 5 47058 Duisburg Germany Tel 49 203 301 0 Fax 49 203 301 10389 info krohne com KROHNE 05 2017 4005720001 AD OPTIBAR 7060 Ex db ia R01en Subjec...

Reviews: