PRE-OPERATION

Pre-operation checks should be made each time you 

need to operate. If any item in the Pre-operation 

check is not working properly, have it inspected and 

repaired before operating the generator.

The condition of a generator is the owner’s 

responsibility. Vital components can start to 

deteriorate quickly and unexpectedly, even if the 

generator is unused.

TIP: Pre-operation checks should be made each time 

the generator is used.

The engine and muffler will be very hot after the 

engine has been run. Avoid touching the engine and 

muffler while they are still hot with any part of your 

body or clothing during inspection or repair.

FUEL

•  Fuel is highly flammable and poisonous. Check 

“SAFETY INFORMATION” (See page 2-5) carefully 

before filling. 

•  Do not overfill the fuel tank, otherwise it may 

overflow when the fuel warms up and expands. 

•  After fill the fuel, make sure the fuel tank cap is 

tightened securely. Immediately wipe off spilled 

fuel with a clean. Use only unleaded gasoline. The 

use of leaded gasoline will cause severe damage to 

the internal engine parts. 

Remove the fuel tank cap 

1. Fill to the red mark

2. Upper level when refuelling

Recommended fuel:

Unleaded gasoline (95 octan) - 

tank capacity: 2,6 liter

TIP: Gasoline will deteriorate after time, and old 

gasoline might cause startup problems.  

Make sure to use fresh gasoline. 

ENGINE OIL

The generator has been shipped without engine oil. 

Do not start the engine until filled with the sufficient 

engine oil. Do not tilt the generator when adding 

engine. This could result in overfilling and damage to 

the engine. 

1. Place the generator on a level surface.

2. Remove the screws (2), and then remove the 

cover (3). 

3. Remove the oil filler cap (1). 

4. Fill with the specified amount of the recommended 

engine oil, and then install and tighten the oil filler 

cap.

5. Install the cover and tighten the screws.

RECOMMENDED ENGINE OIL

Engine oil

SAE SJ 15W-40

Engine oil grade

API Service SE type, or 

higher quality.

Engine oil quantity 0,31 liter

CHECKLIST BEFORE USE

a) FUEL

•  Check fuel level

•  Refill if needed

b) ENGINE OIL

•  Check engine oil level

•  If level is too low, please refill with recommended 

oil until specified level

•  Check if any oil leackages

Never operate the engine in a closed area or it may 

cause unconsciousness and death within a short 

time. Operate the engine in a well ventilated area. 

Before starting the engine, do not connect any 

electric devices.

Always check the condition of the generator before 

use. The generator has been shipped without engine 

oil. Do not start the engine till fill with the sufficient 

engine oil. 

ATMOSPHERIC CONDITIONS

The generator can be used with the rated output load 

at standard atmospheric conditions.

Summary of Contents for GeBe 570812

Page 1: ...POWERMAN 1000is ART NR 570812 MANUAL ...

Page 2: ... og varsel symboler på aggregatet ikke dekke alle farlige forhold Hvis vi ikke gir ekstra forsiktighetsregler for operasjonsprosedyrer metoder eller teknikker betjen generatoren på en slik måte at det garanterer personlig sikkerhet sørg for at ingen skade på generatorsettet oppstår der fra advarsler i denne håndboken og på generatoren før en sikkerhet varsling Du VIL SKADES ALVORLIG dersom anvisni...

Page 3: ...ker måte Hvis generatoren skal kobles til strømnettet hjemme som en standby skal tilkoblingen utføres av en profesjonell elektriker Når lasten er koblet til generator må du sjekke nøye om elektriske koblinger er sikkert og pålitelig Enhver feil tilkobling kan forårsake skade på generatoren Sørg for at aggregatet får tilstrekkelig med kjøling samt at gjørme og vann ikke kommer inn Det kan skade agg...

Page 4: ... før vedlikeholdsarbeid utføres før du forlater enheten og etter at den er slått av En advarsel minner brukeren på at han skal overholde forskrifter for elektrisk sikkerhet som gjelder for stedet der aggregatet brukes En advarsel stiller krav og angir forhåndsregler vedrørende bruk og installasjon av aggregatet Disse skal følges og respekteres av brukeren PRODUKTOVERSIKT Apparat 1 Håndtak 2 Ventil...

Page 5: ...llampen for overbelastning vil lyse rødt dersom det tilkobles og brukes utstyr som krever mer strøm enn aggregatet produserer om inverter overopphetes eller om spenningen øker For å hindre skade på aggregatet og tilkoblet utstyr vil bryter for overbelastning løse ut Det produseres nå ikke strøm til stikkontakten Lampen for drift grønn vil slukke og lampen for overbelastning rød vil fortsette å lys...

Page 6: ...m krever høy startstrøm TANKLOKK 1 Skru av tanklokket ved å dreie det mot urviserne 2 Tanklokket 2 er utrustet med vrider 1 for å åpne og lukke ventilasjonen av bensintanken Vrideren må settes i posisjon ON åpen for å sørge for bensintilførsel til motoren når aggregatet skal brukes For å stenge utluftingen og unngå søling under transport av aggregatet sett vrideren i posisjon OFF lukket JORDINGTER...

Page 7: ... kunne skade motoren Sørg derfor for å bruke så fersk bensin som mulig MOTOROLJE Aggregatet leveres uten motorolje Start ikke motoren før det er fylt opp riktig kvalitet og mengde motorolje 1 Plasser aggregatet på et plant underlag 2 Skru ut skruene 1 ta av sidepanel 2 3 Skru ut oljepåfyllingslokket 3 4 Fyll motorolje i henhold til spesifikasjonene Fyll til øvre gjenge i påfyllingshullet Skru dere...

Page 8: ...n hurtig til deg TIPS For å hindre at aggregatet velter under oppstart hold et godt tak i bærehåndtaket når du drar i startsnoren Slipp ikke startsnoren hurtig tilbake Før den forsiktig tilbake for å unngå skade på startappratet 5 Når motoren har startet vri motorbryteren til posisjon ON DRIFT 4 TIPS Dersom motoren startes med ESC i posisjon ON PÅ og aggregatet ikke belastes og du ønsker å bruke E...

Page 9: ...iet lades Pass på at batteriet lades korrekt i henhold til instruksjoner i manual for batteriet Automatsikringen vil løse ut ved overbelastning av DC kursen dersom batteriet trekker for mye ladestrøm eller om det er foretatt en feilkopling Dersom dette oppstår vent noen minutter før sikringen trykkes inn igjen I tilfelle sikringen fortsetter å løse ut avslutt ladingen og sjekk strømaggregatet even...

Page 10: ...v sensitivt utstyr som PC TV lesebrett datamaskiner elektroniske måleinstrumenter eller elektroniske batteriladere sørg for å holde avstand til strømaggregatet for å unngå elektrisk forstyrrelser fra motoren Ta kontakt med leverandør produsent dersom strømaggregatet skal benyttes som strømkilde til medisinsk utstyr En del elektrisk utstyr og vanlige elektromotorer har svært høy startstrøm og kan p...

Page 11: ... dersom nødvendig Slange for veivhusventilasjon Kontroller slange for sprekkdannelser eller annen skade Skift ved behov Topplokk Fjern sotdannelse i topplokk Skift ved behov Ventilklaring Kontroller og juster med kald motor Generell tilstand Kontroller bolter skruer mutre stag pakninger Utbedre feil etter behov Første oljeskift på motor skal utføres innen 1 måned eller etter 20 timers drift Luftfi...

Page 12: ...nde faktor for motorens ytelse og levetid Bruk kun anbefalt motorolje 1 Plasser strømaggregatet på et horisontalt nivå ved kontroll av oljenivå Ved oljeskift start motoren og la den gå noen minutter for å varmes opp Stopp deretter motoren ved å vri 3 i 1 motorbryter til posisjon OFF Drei deretter også rattet for tank ventilasjon til posisjon OFF lukket 2 Skru ut skruene 1 og ta av sidepanel 2 3 Sk...

Page 13: ...orsiktig for å unngå skader på gnistfangerne 4 Skift gnistfangere dersom de er skadet 5 Tilbakemonter gnistfanger Bruk aldri strømaggregatet på steder hvor det kan oppstå brann uten at gnistfangere er montert som i skogsområder Eventuelle gnister kan forårsake antenning TIPS Ved montering av gnistfanger 7 tilpass til hullet 8 i eksosrøret PÅFYLLINGSSIL FOR BENSIN Bensin er ekstremt brennbart og un...

Page 14: ...asjonen uten at noe er tilkoblet aggregatet Hvor lang tid det vil ta før motoren stopper avhenger av hvor mye bensin som er igjen på tanken etter tømming Bensin er ferskvare Gammel bensin kan forårsake startproblemer Dette forsterkes ved start om vinteren ved lav temperatur Ved lagring over tid anbefales at bensintank og forgasser tømmes for bensin 4 Skru ut skruene 1 og ta av sidepanel 2 5 Tøm fo...

Page 15: ...jon 5 Lydnivå 3 4 belastning 63 5 dB Lpa DC 12 V effekt 12 V 5 A Overbelastning DC Automatsikring AC Varsellampe MOTOR Motor modell R60 i Motor type Luftkjølt 1 sylindret 4 takts OHV bensinmotor Sylindervolum 60 cm Bensin Blyfri bilbensin 95 oktan Tankinnhold 2 6 liter Driftstid v kont Belastning Ca 4 timer Motorolje 0 31 liter Tennplugg A5RTC Startsystem Snorstart Mål BxDxH 450 240 385 mm Vekt 13...

Page 16: ...16 Norsk KOBLINGSSKJEMA 1 kW standardmodell med uttak for parallellkobling 230V 50Hz ...

Page 17: ...ialkabelen fjernes Bruk av PM1000is som er parallellkoplet Ved å benytte spesialkablene som medfølger aggregatene kan 2 stk PM1000is parallell koples for å øke avgitt effekt Følg instruksjonene for sammenkopling Før elektrisk utstyr tilkoples aggregatene les følgende Tips Pass på at utstyr som tilkoples er i god teknisk stand og at elektrisk tilførselskabel ikke er skadet I tilfelle tilkoplet utst...

Page 18: ...ason warnings in this manual and caution signs on the generator may not cover all hazardous circumstances If we do not give extra cautions for operating procedures methods or techniques operate the generator in such ways that helps guarantee personal safety make sure no damage to generator set arises there from warnings in this manual and on the generator preceded by a safety alert You WILL be KIL...

Page 19: ... Use the ground wire with enough electric flux If the generator is to be connected to a home power supply as a standby connection shall be performed by a professional electrician or by another person with proficient electrical skill When the loads are connected to the generator please carefully check whether electrical connections are safe and reliable Any improper connection may cause or damage t...

Page 20: ...before leaving the device and after switching it off A warning reminding the user that he shall conform to regulations of electrical safety applicable to the place where the generating sets are used A warning on the requirements and the precautions to be respected by the user in the case of re supply by generating sets of an installation depending on existing protective measures in this installati...

Page 21: ...INDICATOR LIGHT RED The overload indicator light 1 comes on when an overload of a connected electrical device is detected the inverter control unit overheats or the AC output voltage rises Then the AC protector will trip stopping power generation in order to protect the generator and any connected electric devices The AC pilot light Green will go off and the overload indicator light Red will stay ...

Page 22: ...ted 5000r min Regard less of whether is load connected or not Tip The ESC must not be turned to OFF when using electric devices that require a large starting current such as a compressor of a submergible pump FUEL TANK CAP 1 Remove the fuel tank cap by turning it counterclockwise 2 The fuel tank 2 cap is provided with an air vent knob 1 to stop fuel flow The air vent knob must be turned to ON This...

Page 23: ...eteriorate after time and old gasoline might cause startup problems Make sure to use fresh gasoline ENGINE OIL The generator has been shipped without engine oil Do not start the engine until filled with the sufficient engine oil Do not tilt the generator when adding engine This could result in overfilling and damage to the engine 1 Place the generator on a level surface 2 Remove the screws 2 and t...

Page 24: ...m falling over when pulling the recoil starter 5 After the engine starts warm up the engine until the engine does not stop when the choke knob is returned to the ON position 4 TIP When starting the engine with the ESC ON and there is no load on the generator if you wish to use the Ecothrottle system turn the Ecothrottle switch to the ON position after the engine has warmed up for 3 or 5 minutes In...

Page 25: ...e negative battery terminal Do not reverse these positions Connect the battery charger leads to the battery terminals securely so that they are not disconnected due to engine vibration or other disturbances Charge the battery in the correct procedure by following instructions in the owner s manual for the battery The DC protector turns off automatically if current above the rated flows during batt...

Page 26: ... the generator a sufficient distance away to prevent electrical interference from the engine Also ensure that electrical noise from the engine does not interfere with any other electrical devices located near the generator If the generator is to supply medical equipment advice should first be obtained by the manufacturer a medical professional or hospital Some electrical appliances or general purp...

Page 27: ...ssary Crankcase breather hose Check hose weather for cracks or damage Replace if necessary Cylinder head Decarbonizes cylinder head more frequently Replace if necessary Valve clearance Check and adjust when engine is cold Fittings fasteners Check all fittings and fasteners Correct if necessary Initial replacement of the engine oil is after before one month or after 20 hours of operation The air fi...

Page 28: ...the professional knowledge specialized date and equipment to do so properly ENGINE OIL REPLACEMENT Avoid draining the engine oil immediately after stopping the engine The oil is hot and should be handled with care to avoid burns 1 Place the generator on a level surface and warm up the engine for several minutes Stop the engine and turn the 3 in 1 switch knob and fuel tank cap air vent knob to OFF ...

Page 29: ...leaning use the wire brush lightly to avoid damaging or scratching the muffler screen and spark arrester 4 Check the muffler screen and spark arrester replace if it damage 5 Install spark arrester If using in areas prone to fires such as forest or woods never use an engine without an appropriate spark arrester TIP Align the spark arrester projection 7 with the hole 8 in the muffler pipe 6 Install ...

Page 30: ...ny electrical devices Unloaded operation Duration of the running engine depends on the amount of the fuel left in the tank Fuel is highly flammable and poisonous Check SAFETY INFORMATION Immediately wipe off spilled fuel with a clean dry soft cloth since fuel may deteriorate painted surfaces or plastic parts 4 Remove the screws and remove the cover 5 Drain the fuel from the carburetor by loosening...

Page 31: ... dB Lpa DC Output 12 V 5 A Overload DC Non fuse Protector AC Control by inverter overload protect program Engine Engine modell R60 i Engine type Single cylinder 4 Stroke forced air cooling OHV Displacement 60 cm Fuel type Unleaded Gasoline Fuel capacity 2 6 liter Continue Running Time at rated power Ca 4 hour Oil Tank Capacity 0 31 liter Spark Model No A5RTC Starting mode Recoil start Length Width...

Page 32: ...32 English ELECTRICAL SCHEMATIC DIAGRAM 1 kW with Parallel Receptacle ...

Page 33: ... engines turned off Always remove cable if only using one generator How to use PM1000is in parallel operation By using the cable kit you can connect 2 pcs PM1000is in parallel operation to increase output power Before connecting the electrical appliance read the following TIP Please ensure that the appliance that is connected is in good technical condition and that the power cable is not damaged I...

Page 34: ...34 ...

Page 35: ...35 ...

Page 36: ...krefter at dette produktet er i samsvar med følgende direktiver og standarder Intygar att denna produkt överensstämmer med kraven i följande direktiv och standarder Product Inverter generator Strømaggregat Elverk Model Gebe 570812 PM1000is Machinery Directive 2006 42 EC EN ISO 8528 13 2016 EMC Directive 2014 30 EU EN 55012 2007 A1 EN61000 6 1 2007 2000 14 EC with amendment 2005 88 EC EN ISO 3744 2...

Reviews: