4. OPERATING
PRINCIPLE
The BASE and CATALYST materials are sent to the mixing machine from 2 pumps or pressure tanks.
Each material crosses a piloted valve, a meter. The cycle begins with the simultaneous opening of the
CATALYST and BASE valves. The 2 meters send their informations to the computer that shuts off the
catalyst valve when the computerized mixing ratio is reached.
The mixing process is based on a base constant flow. The catalyst flow is injected low in frequency and
regulated in pressure. The injection is made directly into the base flux at the mixer level.
The automaton (PLC) checks continuously the mixing ratio and if it notices a fault that it cannot correct, an
alarm is activated. The machine goes on safety mode.
SB
B
VP4
VTA
CA
CB
A
SA
VP6
VP2B
VP3
VP1
VP2A
MEL
VP1
Base solvent piloted valve (SA)
VP5
Base test piloted valve
VP2B Catalyst piloted valve (B)
VP6
Injection piloted valve
VP2A Base piloted valve (A)
CA
Base meter
VP3
Catalyst solvent piloted valve (SB)
CB
Catalyst meter
VP4
Catalyst test piloted valve
MEL
Mixer