KREMLIN REXSON
N° : 578.046.110-UK-1004
CAUTION :
Before any action on the pump, shut off the compressed air supply and
depressurize the systems.
FLUID SECTION OR AIR MOTOR REPLACEMENT
The pump is manufactured under the ATEX agreement and can not be modified.
KREMLIN REXSON will not be held responsible for any failure to comply with that
instruction.
Guards (motor cover, coupling shields, connectors,…) have been designed for a
safe use of the equipment.
The manufacturer will not be held responsible for bodily injury or failure and / or
property damage due to destruction, the overshadowing or the partial or total
removal of the guards.
Position the air motor piston in a high position before shutting off the compressed air and before
depressurizing the system.
Disassemble the pump from its bracket by removing the 2 nuts and put aside the pump.
Remove the third nut that holds on the third rod.
Unscrew the screw located on the protection housing
with an Allen wrench of 5. Slide the transparent part of
the protection housing to access to the parts of the
coupling.
Extract the pin and the coupling axis. Disassemble the air motor from the fluid section.
When changing the air motor :
Remove the hood of the old air motor by unscrewing the 3 screws and put aside the 2 air regulators
and the gauges.
Remove the hood of the new air motor by unscrewing the 3 screws .
Disassemble the collector equipped with the 2 nipples by unscrewing the 4 screws .
Assemble the air regulators and the gauges on the 2 nipples.
Fix the assembly on the bare air motor. Replace the hood and fix it by means of the 3 screws.
Place the protection housing on the material flange of the fluid section, assemble the air motor and
the fluid section with the coupling axis and the pin, the rods and the nuts.
Slide the transparent part of the protection housing to close it. Align the hole located on the
transparent part of the protection housing and the srew of the protection housing. Screw the screw
with an Allen wrench of 5 to fix the protection housing.
Assemble the new air motor and the fluid section. Place the pump on the bracket.
When changing the fluid section :
Place the protection housing on the material flange of the new fluid section, assemble the air motor
and the fluid section with the coupling axis and the pin, the rods and the nuts.
Slide the transparent part of the protection housing to close it. Align the hole located on the
transparent part of the protection housing and the srew of the protection housing. Screw the screw
with an Allen wrench of 5 to fix the protection housing.
Position the whole on the wall mounted unit.