CAUTION :  

Before any action on the pump, shut off the compressed air supply and 
depressurize the systems. 

 

 

ƒ

 

FLUID SECTION OR AIR MOTOR REPLACEMENT   

The pump is manufactured under the ATEX agreement and can not be modified. 

KREMLIN REXSON will not be held responsible for any failure to comply with that 
instruction. 

 

Guards (motor cover, coupling shields, connectors,…) have been designed for a 

safe use of the equipment. 

The manufacturer will not be held responsible for bodily injury or failure and / or 

property damage due to destruction, the overshadowing or the partial or total 
removal of the guards.  

 

Position the air motor piston in a high position before shutting off the compressed air and before 
depressurizing the system. 

Disassemble the pump from its bracket by removing the 2 nuts and put aside the pump. 

Remove the third nut that holds on the third rod.  

Unscrew the screw located on the protection housing 
with an Allen wrench of 5. Slide the transparent part of 
the protection housing to access to the parts of the 
coupling. 

 

 

Extract the pin and the coupling axis. Disassemble the air motor from the fluid section.  

 

When changing the air motor : 

Remove the hood of the old air motor by unscrewing the 3 screws and put aside the 2 air regulators 
and the gauges. 

Remove the hood of the new air motor by unscrewing the 3 screws . 

Disassemble the collector equipped with the 2 nipples by unscrewing the 4 screws .  

Assemble the air regulators and the gauges on the 2 nipples. 

Fix the assembly on the bare air motor. Replace the hood and fix it by means of the 3 screws. 

Place the protection housing on the material flange of the fluid section, assemble the air motor and 
the fluid section with the coupling axis and the pin, the rods and the nuts.   

Slide the transparent part of the protection housing to close it. Align the hole located on the 
transparent part of the protection housing and the srew of the protection housing. Screw the screw 
with an Allen wrench of 5 to fix the protection housing. 

 

Assemble the new air motor and the fluid section. Place the pump on the bracket.  

When changing the fluid section : 

Place the protection housing on the material flange of the new fluid section, assemble the air motor 
and the fluid section with the coupling axis and the pin, the rods and the nuts.  

Slide the transparent part of the protection housing to close it. Align the hole located on the 
transparent part of the protection housing and the srew of the protection housing. Screw the screw 
with an Allen wrench of 5 to fix the protection housing. 

 

Position the whole on the wall mounted unit. 

Summary of Contents for AIRMIX 20-15

Page 1: ...p Please read and clearly understand all documents relating to this equipment professional use only PICTURES AND DRAWINGS ARE NON CONTRACTUAL WE RESERVE THE RIGHT TO MAKE CHANGES WITHOUT PRIOR NOTICE KREMLIN REXSON l 150 avenue de Stalingrad 93 245 STAINS CEDEX France 33 0 1 49 40 25 25 Fax 33 0 1 48 26 07 16 www kremlin rexson com ...

Page 2: ...d air motor by unscrewing the 3 screws and put aside the 2 air regulators and the gauges Remove the hood of the new air motor by unscrewing the 3 screws Disassemble the collector equipped with the 2 nipples by unscrewing the 4 screws Assemble the air regulators and the gauges on the 2 nipples Fix the assembly on the bare air motor Replace the hood and fix it by means of the 3 screws Place the prot...

Page 3: ... on the control fork assembly 9 Reinstall the new air motor valve 15 and block it on the control rod 9 via the two flat parts located at its end Reinstall the cover 19 and fix it by means of the 4 screws 21 Reinstall the hood 23 with its 3 screws 24 Before reassemblying the different components Clean the parts with the appropriate cleaning solvent Install new seals if it is necessary after having ...

Page 4: ... lb 560 420 005 Medium strength Aneorobic Pipe sealant Loctite 577 SUCTION VALVE Unscrew the ball seat 10 the valve comes out the cylinder The ball cage 14 is secured on the seat 10 by means of the circular rush 13 Reinstall the ball seat 10 and check if the seal is worn or damaged 11 EXHAUST VALVE Unscrew the cylinder 7 and pull it downwards Unscrew the exhaust seat 16 by holding on the valve sup...

Page 5: ...ton rod 20 from top to bottom into the new cartridge 4 to avoid damaging the inside seal Place the whole into the pump flange 1 The cartridge is equipped with a seal 5 Fix the cartridge by means of the circlips 3 Reinstall the other parts and check if the seals are installed Before reassemblying the different components Clean the parts with the appropriate cleaning solvent Install new seals if it ...