KREMLIN REXSON
- 6 -
N° : 578.156.110-UK-1202
Assembly
To prepare an assembly,which consists of bellows-skirt-flange, you must :
- Install a new bellows (5) into the bellows flange (4).
- Change the seal (13).
Lubricate the seal (13) and the flange (4) (grease, type A1).
- Insert the assembly in the bearing (3).
- When installing the bellows, push it into skirt (6) firmly.
- Install the upper bellows flange (14).
Slide the bellows-skirt-flange assembly along the air motor rod.
Orientate it and tighten it on the air motor base by means of the 3 screws (9).
Nota :To make easier the assembly, you can remove one of the 3 pump tie-rods (7).
Couple the fluid sub-assembly (B) with the suction sub-assembly (A).