5.4.2 Long-term shut-down
Fig. 5: Long-term shut-down
1.
Disrupt the spraying process by releasing the pull lever ( Fig. 5/1).
2.
Close the material supply and switch off the pump if necessary.
3.
Release the residual energy by activating the pull lever ( Fig. 5/1).
4.
Chapter 6.4 ‘Clean hand-held spray gun’ on page 26
5.
Clean parts with adhering residual material in an appropriate manner.
6.
Always store the hand-held spray gun well out of the reach of unauthorised persons. If nec-
essary, unscrew the material hose and clean dirty parts, disconnect the earth connection
and lock away the hand-held spray gun.
DANGER!
Risk of fatal injury due to toxic, flammable or explosive material
High risk potential during the storage and transport of the hand-held spray gun still containing
toxic, flammable or explosive material or cleaning products.
–
Properly clean the hand-held spray gun before storage and transport so that there is no
toxic, flammable or explosive products inside.
ENVIRONMENT!
Environmental hazard due to incorrect disposal!
Incorrect disposal may cause environmental hazards.
–
After the useful life of the device has been exhausted, dispose of it via the commercial
waste.
–
Properly dispose of potential spray fluid residue separately from the device.
–
If in doubt, obtain information about environmentally-appropriate disposal with the local
municipalities or specialized disposal companies.