8 Troubleshooting
Personnel:
n
Qualified personnel
8.1 Troubleshooting table
If the fault is not included in the following table or if it cannot be eliminated with the measures
described, contact Customer Care.
Error
Cause
Remedy
Agitator does not turn
Compressed-air supply dis-
rupted
Check compressed-air supply
Leak at bearing block
Bearing block sealings defec-
tive
Have bearing block sealings
replaced by manufacturer (con-
tact information on last page)
Unusual sounds during oper-
ation
Defective bearing
Have bearing replaced by manu-
facturer (contact information on
last page)
Fluid is not mixed thoroughly
Worn agitator. Agitator made
of unsuitable material.
Use suitable agitator
Fluid is poorly mixed
Unfavourable agitator geom-
etry
Use suitable agitator