7.5 Replace valve parts
1.
Clean diaphragm pump (
Chapter 7.4 ‘Clean the diaphragm pump’ on page 29
2.
Make sure that the compressed air supply is switched off and secured against a restart.
3.
Reduce the fluid pressure by activating the extraction point.
Fig. 9: Valve parts
4.
Carefully unscrew each screw ( Fig. 9/1).
5.
Disconnect the pressure and suction connection ( Fig. 9/2).
6.
Remove the valve ball ( Fig. 9/3) and seal ( Fig. 9/4).
The valve seats ( Fig. 9/5) can only be replaced by Krautzberger GmbH. You have to
return the pressure and suction connection ( Fig. 9/2) for this purpose. See the last
page for contact information.
7.
Check all parts for damage and wear and replace them as necessary.
8.
Chapter 7.6 ‘Replace the diaphragm’ on page 32
).
Operating instructions
T-Dok-300-GB-Rev.1
[email protected], www.krautzberger.com
GB–30