Page
8
of
20
APPLIANCE INSTALLATION (cont.)
Installation Clearance
Leveling
Ensure the floor where the unit is to be located is level. (It is ok to slope down from front to rear by up to 1/4” – it mustn’t
slope from the rear to the front.)
Stabilizing
All models are supplied with casters for your convenience. It is very important, however, that the cabinet be installed in a
stable condition with the front wheels locked while in use. Should it become necessary to lay the unit on its side or back for
any reason, allow at least 24 hours before start-up to allow compressor oil to flow back into place. Failure to meet this
requirement can cause compressor failure and unit damage which isn’t covered by the appliance warranty.
Reversing The Door (Single Door Models Only)
Single door models can be converted from right-hand hinged to left-hand hinged and vice-versa by removing the door
hinges from both the door and unit, reversing their locations and reattaching them, and re-hanging the door upside-down.
NOTICE:
Unit repairs will not be subject to standard unit warranties if due to improper installation procedures or
utilizing an unqualified installer technician to commission the unit.
Electrical Connection
Refer to the amperage data on the
Technical Information
table, the serial tag, your local code or the National Electrical Code
to be sure that unit is connected to the proper power source.
DANGER
The unit must be turned OFF and disconnected from the power source whenever performing
service, maintenance functions or cleaning the refrigerated area. Failure to comply may
result in Death or Severe Personnel Injury.
12” (305mm) clear space
2”
51mm
Single Door Models
Double Door Models
27 in
686 mm
27 in
686 mm
60.5 in
1537 mm
Max Door Swing
Clearance
60.5 in
1537 mm
Max Door Swing
Clearance