1.
Connect to power circuit.
Make sure that the main switch is in the „OFF“ position.
2.
Connect machine to water mains (2 - 8 bar pre-pressure). Inside diameter of hose mini-
mum 1/2“. The water storage tank is filled with water. The float valve shuts the water intake
as soon as the tank is full.
3.
Screw HP hose tightly to the cleaner.
4.
Push on HP hose to gun.
5.
Screw together HP hose and gun
pressure-tightly.
18
Commissioning
6.
Always check oil level prior to operation!
Open the machine.
Do not start the machine if the oil level is not
between the two markings on the oil-level
glass. Refill with oil if necessary. See page 23.
Take care that all screw connections are pressure-tight. A leakage of
gun, high-pressure hose or hose drum has to be repaired at once.
Leakages lead to an increased wear and to a possible malfunction of the
delayed motor cut-out.