22
Type plate (on hand)
Operating manual (on hand)
Protective covering, -device
Pressure line (tightness)
Pressure gauge (function)
Float valve (tightness)
Spraying device (marking)
HD-hose / connector (damage, marking)
Safety valve opens at 10 % / 20 % exceeding of operang pr.
Power cable (damage)
Protective conductor (connectedt)
On / Off switch
Used chemicals
Allowed chemicals
High-prsure nozzle
Operating pressure..................bar
Switch off pressure................bar
Conductor reist. not exceeded / value
Insulation
Leakage current
Gun locked
The appliance was checked by an expert according to the Guidelines for Liquid
Spray Equipment, the defects found have been rectified so that the Labour Safety can
be confirmed.
The appliance was checked by an expert according to the Guidelines for Liquid
Spray Equipment. The Labour Safety cannot be confirmed unless the defects found are
rectified by repair or replacement of the faulty parts
The next retest according to the Guidelines for Liquid Spray Equipment has to be carried
out by : Month Year
Place,
date
Signature
Inspection report for HP cleaners
Inspection report on annually carried out Labour Safety Inspection (UVV) according to
the Guidelines for Liquid Spray Equipment. (This inspection sheet serves as proof for
the completion of the retest and must be kept carefully!)
Kränzle test seal: Order.no..UVV200106
Scope of inspection o.k. yes no repaired
Inspection data determined value set value
Inspection result (tick)
Owner:
Address:
Type:
Serial no.:
Rep.-order-no.: