54
Type plate (on hand)
Operating manual (on hand)
Protective covering, -device
Pressure line (tightness)
Pressure gauge (function)
Float valve (tightness)
Spraying device (marking)
HP-hose/ connector (damage, marking)
Safety valve opens at 10% / 20% excess
Pressure reservoir
Heating oil line (tightness)
Solenoid valve (function)
Thermostat (function)
Flow controller (function)
Power cable (damage)
Power plug (damage)
Protective conductor (connected)
Emergency Off Switch (function)
On/Off-switch
Water quantity safety device (function)
Used chemicals
Allowed chemicals
High-pressure nozzle
Operating pressure ............bar
Cutting-off pressure.............bar
Efficiency rating...................%
Conductor resist. not exceeded / value:
Insulation
Leakage current:
Gun locked
Inspection report on annually carried out Labour Safety Inspection (UVV) according to the
Guidelines for Liquid Spray Equipment. (This inspection sheet serves as proof for the completion of
the retest and must be kept carefully!) Kränzle-Test Stamp Mark: Order Number UVV200106
Scope of inspection: ok yes no repaired
Inspection data determ. value set value
Owner:
Address:
Type
therm
:
Serial no.:
Rep.-order-no.:
The appliance was checked by an expert according to the Guidelines for Liquid Spray
Equipment, the defects found have been rectified so that the Labour Safety can be confirmed.
The appliance was checked by an expert according to the Guidelines for Liquid Spray
Equipment. The Labour Safety cannot be confirmed unless the defects found are rectified by
repair or replacement of the faulty parts.
The next retest according to the Guidelines for Liquid Spray Equipment has to be carried out
by: Month Year
Place, Date
Signature
Inspection result (tick)
Inspection report for HP cleaners
Summary of Contents for 602 E-M 18
Page 30: ...Complete assembly 30 ...
Page 32: ...32 Electronics switchbox 38 37 42 39 ...
Page 34: ...Water supply 34 ...
Page 38: ...Electric module 18 24 kW 38 24 ...
Page 40: ...40 Electric module 36 48 kW 23 ...
Page 42: ...Unloader valve and pressure switch 42 ...
Page 48: ...48 Flow Safety Block Adjustment must be approx 15 above the operating pressure ...