8x4 HDMI Matrix Switcher Front Panel 

Feature 

Function 

IR

 Indication LED

 

Lights yellow when receiving signals from the infrared remote control transmitter 

IR

 Receiver

 

Signal receiver for the infrared remote control transmitter   

POWER

 LED 

Lights when the device is turned on 

ALL

 Button 

Press followed by an input button to connect the selected input to all outputs 

For example, press ALL and then Input button # 2 to connect input # 2 to all the outputs 

OFF

 Button 

Press after pressing an output button to disconnect the selected output from the inputs. To 
disconnect all the outputs, press ALL followed by OFF  

SELECT 

Buttons

 

OUT 

(1 to 4)

 

Press to select an output to switch followed by an input (also used for storing machine 
setups (see 

Sectio

 6.3

IN

 (1 to 8)

 

Press to select the input to switch after selecting an output (also used for storing machine 
setups (see 

Sectio

 6.3

STO 

Button

 

Press to store the current switching setting to a preset (see 

Sectio

 6.3

) 

RCL 

Button

 

Press to recall the current switching setting from a preset (see 

Sectio

 6.3

) 

10 

LOCK 

Button

 

Press and hold to toggle the locking/release of the front panel buttons. 
When storing or recalling presets, press to store or recall the preset (see 

Sectio

 6.3

) 

11 

EDID 

Button

 

Press to capture the EDID (see 

Sectio

 6.2

12 

OUTPUT/INPUT 

7-segment LED 

Display

 

Displays the input currently switched to the output which is marked above each input   

im Vertrieb von

            CAMBOARD Electronics

www.camboard.de

Tel. 07131 911201
Fax 07131 911203

[email protected]

Summary of Contents for VS-84HN

Page 1: ...RAMER ELECTRONICS LTD USER MANUAL MODEL VS 84HN 8x4 HDMI Matrix Switcher P N 2900 300157 Rev 7 im Vertrieb von CAMBOARD Electronics www camboard de Tel 07131 911201 Fax 07131 911203 ce info camboard d...

Page 2: ...im Vertrieb von CAMBOARD Electronics www camboard de Tel 07131 911201 Fax 07131 911203 ce info camboard de...

Page 3: ...and Protocol 3000 15 6 6 Connecting via RS 232 15 6 7 Connecting via Ethernet 15 6 8 Upgrading the Firmware 17 7 Technical Specifications 18 8 Default Communication Parameters 19 9 Default EDID 20 10...

Page 4: ...on GROUP 1 Distribution Amplifiers GROUP 2 Switchers and Routers GROUP 3 Control Systems GROUP 4 Format Standards Converters GROUP 5 Range Extenders and Repeaters GROUP 6 Specialty AV Products GROUP 7...

Page 5: ...cables we recommend Kramer high performance high resolution cables to avoid interference deterioration in signal quality due to poor matching and elevated noise levels often associated with low quali...

Page 6: ...002 96 EC aims to reduce the amount of WEEE sent for disposal to landfill or incineration by requiring it to be collected and recycled To comply with the WEEE Directive Kramer Electronics has made arr...

Page 7: ...nsures Plug and Play operation for HDMI systems Kramer reKlocking Equalization Technology that rebuilds the digital signal to travel longer distances A lock button to prevent unwanted tampering with t...

Page 8: ...OUT 1 to 4 Press to select an output to switch followed by an input also used for storing machine setups see Section 6 3 7 IN 1 to 8 Press to select the input to switch after selecting an output also...

Page 9: ...Gateway 192 168 1 1 Depress the button while powering on the device The device powers up with the factory default IP parameters 18 REMOTE IR Opening Connect to an external IR receiver for controlling...

Page 10: ...This distance can be extended to up to 60 meters when used with three extension cables Model C A35M A35F 50 Before using the external IR receiver be sure to arrange for your Kramer dealer to insert th...

Page 11: ...nstalling in a Rack 4 Installing in a Rack This section provides instructions for rack mounting the unit im Vertrieb von CAMBOARD Electronics www camboard de Tel 07131 911201 Fax 07131 911203 ce info...

Page 12: ...ources for example DVD players to the IN HDMI connectors You do not have to connect all the sources 2 Connect the four OUT HDMI connectors to up to four HDMI acceptors for example LCD displays with bu...

Page 13: ...Connecting the VS 84HN 8x4 HDMI Matrix Switcher Figure 3 Connecting the VS 84HN 8x4 HDMI Matrix Switcher im Vertrieb von CAMBOARD Electronics www camboard de Tel 07131 911201 Fax 07131 911203 ce info...

Page 14: ...the firmware see Section 6 8 6 1 Switching an Input to an Output To switch an input to an output Press an output button followed by an input button to switch the selected input to the selected output...

Page 15: ...flashing 6 2 2 Acquiring the EDID from Different Outputs to Different Inputs To acquire the EDID from several outputs for example OUT 1 to IN 1 and OUT 4 to IN 3 1 Connect the display devices to the...

Page 16: ...ut 2 1 Press the EDID and STO buttons simultaneously and hold them for 3 seconds Both buttons flash 2 Press the input for example Input 2 to which the EDID is to be copied The selected input number fl...

Page 17: ...times out To recall a preset for example preset 10 1 Press the RCL button The RCL button flashes 2 Press the relevant OUT or IN button that stored the preset for example IN 6 preset 10 3 Press the RC...

Page 18: ...onnect the RS 232 9 pin D sub on the rear panel of the VS 84HN via a 9 wire straight cable only pin 2 to pin 2 pin 3 to pin 3 and pin 5 to pin 5 need to be connected to the RS 232 9 pin D sub port on...

Page 19: ...al Area Connection Properties 4 Select Properties The Local Area Connection Properties window appears 5 Select the Internet Protocol TCP IP and click the Properties Button see Figure 5 Figure 5 Local...

Page 20: ...connect the Ethernet port of the VS 84HN to the Ethernet port on a network hub or network router via a straight through cable with RJ 45 connectors 6 8 Upgrading the Firmware For instructions on upgra...

Page 21: ...ons infrared remote control transmitter RS 232 Ethernet OPERATING TEMPERATURE 0 to 40 C 32 to 104 F STORAGE TEMPERATURE 40 to 70 C 40 to 158 F HUMIDITY 10 to 90 RHL non condensing DIMENSIONS 19 x 7 x...

Page 22: ...1 0x01 0x81 0x81 0x81 Example Output 1 to Input 1 AV 1 1 CR Switching Protocol P2000 P3000 P3000 P2000 Command 0x38 0x80 0x83 0x81 Command P2000 CR Front Panel Press and hold Output 1 and Output 3 si...

Page 23: ...nge 31 94kHz Vertical scan range 50 85Hz Video bandwidth 170MHz CVT standard Not supported GTF standard Not supported Additional descriptors None Preferred timing Yes Native preferred timing 1280x720p...

Page 24: ...0Hz 16 9 Modeline 1920x1080 74 250 1920 2448 2492 2640 1080 1084 1094 1124 interlace hsync vsync Detailed timing 4 1280x720p at 60Hz 16 9 Modeline 1280x720 74 250 1280 1390 1430 1650 720 725 730 750 h...

Page 25: ...physical address 1 0 0 0 Maximum TMDS clock 165MHz Report information Date generated 08 03 2011 Software revision 2 52 0 857 Data source Real time 0x0031 Operating system 5 1 2600 2 Service Pack 3 im...

Page 26: ...s set as the input number to be switched If switching is done using the machine s front panel these bits are set with the INPUT NUMBER switched For other operations these bits are defined according to...

Page 27: ...performs the instruction and if the instruction is performed due to a keystroke operation on the front panel then these codes are sent For example if the HEX code 01 85 88 83 was sent from the PC the...

Page 28: ...chine which is being addressed not to the system For example if six 16X16 matrices are configured to make a 48X32 system 48 inputs 32 outputs the reply to the HEX code 3E 82 81 82 ie request the numbe...

Page 29: ...Delimiter Command SP Parameter_1 Parameter_2 CR 11 1 1 2 Command String Formal syntax with commands concatenation and addressing Start Address Body Delimiter device_id Command_1 Parameter1_1 Parameter...

Page 30: ...more than one command Commands are separated by a pipe character Message starting character For host command query For device response Device ID Optional for K NET K NET Device ID followed by Query s...

Page 31: ...s Some commands have short name syntax in addition to long name syntax to allow faster typing The response is always in long syntax 11 1 6 Chaining Commands Multiple commands can be chained in the sam...

Page 32: ...et count End User LDEDID Load EDID data User SW Internal LOCK FP LCK Lock front panel Administrator LOCK FP LCK Read Lock front panel End User MODEL Read device model End User P2000 Switch to protocol...

Page 33: ...im Vertrieb von CAMBOARD Electronics www camboard de Tel 07131 911201 Fax 07131 911203 ce info camboard de...

Page 34: ...be found We welcome your questions comments and feedback Web site www kramerelectronics com E mail info kramerel com P N 2900 300157 Rev 7 SAFETY WARNING Disconnect the unit from the power supply bef...

Reviews: