16
VS-3232DN - Connecting the VS-3232DN
5.1.1
EDID Numbering Examples
The following EDID configuration is based on the port numbering shown in
and lists requested switching configurations and their results.
EDID Request
EDID Sent
From OUT 11
Blank (256 bytes of 0xFF)
From IN 13
None (error message displayed)
AV data flow is:
source
>
VS-3232DN
>
display
. EDID information
flow is:
display
>
VS-3232DN
>
source
, which means that the EDID
input is the display side and the EDID output is the AV source side.
This is the reverse of the AV data flow direction.
When assigning EDIDs, note that the top row of the LCD display labeled OUTPUTS
relates to the ports connected to the sources (AV inputs), and the bottom row of the
LCD display labeled INPUTS relates to the ports connected to displays (AV
outputs).
In
, the EDID from EDID input 8 (
VS-3232DN
Output port 8) has been
assigned to all EDID outputs (
VS-3232DN
Input ports).
Figure 6: EDID Numbering Assignment
5.2
Connecting to the VS-3232DN via RS-232
You can connect to the
VS-3232DN
via an RS-232 connection using, for example,
a PC. Note that a null-modem adapter/connection is not required.
To connect to the VS-3232DN via RS-232
:
•
Connect the RS-232 9-pin D-sub rear panel port on the
VS-3232DN
unit via a
9-wire straight cable (only pin 2 to pin 2, pin 3 to pin 3, and pin 5 to pin 5 need
to be connected) to the RS-232 9-pin D-sub port on your PC.