Kramer Electronics Ltd.
VS-3232DN-EM
– Using the Configuration Menus
26
Setup Menu
—
7: EDID, Assignment to an Input
This option assigns an EDID to between one and eight inputs in non-volatile storage. More
than eight EDID assignments must be assigned in multiple batches.
Each input on the
VS-3232DN-EM
has a factory default EDID loaded (see
). The EDID for each input can be changed independently via the menu
(described below) or by uploading an EDID binary file to each input via the RS-232 port.
It is necessary to have a display/device connected to the output from which you want to read
the EDID. Failure to do so results in the default EDID being written to storage.
To assign an EDID to between one and eight inputs:
1. Press MENU.
The Setup Menu options are displayed.
2. Press 7 (EDID) on the numeric keypad (see
The following is displayed:
SETUP EDID
ENT to View EDID and Set EDID
3. Press ENT.
The current EDID matrix configuration is displayed.
4. Using the numeric keys, enter the input in which to store the EDID (in this example, 08),
and enter the output (in this example, 05) from which to read the EDID.
The following is displayed:
01 02 03 04 05 06 07 08
05 out05 => in08
The TAKE button flashes.
5. Repeat Step 4 for up to eight inputs.
6. Press TAKE.
The EDID is stored and passed through to the input.
The display reverts to the output/input display.
To view the EDID assignments:
1. Press MENU.
The Setup Menu options are displayed.
2. Press 7 (EDID) on the numeric keypad (see
The following is displayed:
SETUP EDID
ENT to View EDID and Set EDID