Step 3: Install the VS-211XS and VS-411XS
Install
VS-411XS
using one of the following methods:
•
Attach the rubber feet and place the unit on a flat surface.
•
Fasten a bracket (included) on each side of the unit and attach it to a flat surface
www.kramerav.com/downloads/VS-411XS
•
Mount the unit in a rack using the recommended rack adapter
www.kramerav.com/product/VS-411XS
•
Ensure that the environment (e.g., maximum ambient temperature &
air flow) is compatible for the device.
•
Avoid uneven mechanical loading.
•
Appropriate consideration of equipment nameplate ratings should be
used for avoiding overloading of the circuits.
•
Reliable earthing of rack-mounted equipment should be maintained.
•
Maximum mounting height for the device is 2 meters.
Step 4: Connect the inputs and outputs
Always switch OFF the power on each device before connecting it to your
VS-211XS
. For best results, we recommend that
you always use Kramer high-performance cables to connect AV equipment to the
VS-211XS
.
VS-211XS
and
VS-411XS
are
identical except for the number of inputs.
Connect the Audio Output:
To a balanced
stereo audio
acceptor:
To an
unbalanced
stereo audio
acceptor:
Setting the DIP-Switches
All DIP-switches are set to Off (up) by default. DIP-switch changes take effect immediately.
#
Feature
Dip-Switch Settings
1
Switching Mode
OFF (up)
– Auto-switching mode.
ON (down)
– Manual mode.
2
Auto-switching Mode
OFF (up)
– Last connected switching mode: the last detected active source is auto-switched to the output.
ON (down)
– Priority switching mode: the device
switches the source with the highest priority to the output.
3
CEC Notifications
OFF (up)
– CEC notifications enabled.
ON (down)
– CEC notifications disabled.
4
Reserved for Factory Use
It is mandatory to keep set to OFF (up).
For optimum range and performance use the recommended Kramer cables available at
www.kramerav.com/product/VS-411XS
Step 5: Connect the power
Connect the power adapter and cord to
VS-211XS
/
VS-411XS
and plug it into the mains electricity.
Safety Instructions (See
for updated safety information).
Caution:
•
For products with relay terminals and GPI\O ports, please refer to the permitted rating for an external connection, located next to the terminal or in the User Manual.
•
There are no operator serviceable parts inside the unit.
Warning:
•
Use only the power cord that is supplied with the unit.
•
Disconnect the power and unplug the unit from the wall before installing.
Step 6: Control VS-211XS
and VS-411XS
Operate
VS-211XS
and
VS-411XS
:
•
Remotely, by IP
or RS-232
serial commands transmitted
by a touch screen system, PC,
or other serial controller.
•
Embedded web pages via the
Ethernet.
RS-232 Control / Protocol 3000
Baud Rate:
115,200
Parity:
None
Stop Bits:
1
Data Bits:
8
Command Format:
ASCII
Example: (Switch video input 2 to the output): #ROUTE 1,1,2<CR>
Default IP Parameters
– Set to DHCP On
Fallback IP Address:
192.168.1.39
UDP Port #:
50000
Fallback Subnet Mask:
255.255.255.0
TCP Port #:
5000
Fallback Gateway:
192.168.1.1
User/Password:
Admin/Admin
Host name
VS-211XS-xxxx (where xxxx are the last 4 digits of the S/N)
When using
VS-211XS
for the first time, the fallback IP address is set until DHCP server is discovered and a new IP address is acquired.
DHCP discovery is retried every 1 minute, approximately.
To discover IP address:
•
Connect to device via Eth and browse to default host name (e.g.,
http://
VS-211XS
-0024
), where xxx are last digits of the S/N;
alternatively, perform factory reset (via reset button) and browse to fallback IP address.
•
Connect to subnet via a router with
built-in DHCP server
(a basic home router will do) to subnet for identifying subnet-connected
devices via router web-UI, using their unique hostname and/or L2 MAC address.