Kramer Electronics Ltd.
VP-444
– RS-232/Ethernet (UDP) Communication Protocol
41
RESET
Function
Permission
Transparency
Set:
RESET
Administrator
Public
Get:
-
-
-
Description
Syntax
Set:
Reset device
#RESET
␍
Get:
-
-
Response
~nn@
RESET
␠
OK
␍␊
Notes
To avoid locking the port due to a USB bug in Windows, disconnect USB connections immediately after
running this command. If the port was locked, disconnect and reconnect the cable to reopen the port.
VERSION?
Function
Permission
Transparency
Set:
-
-
-
Get:
VERSION?
End User
-
Description
Syntax
Set:
-
-
Get:
Get version number
#VERSION?
␍
Response
~nn@
VERSION
␠
firmware_version
␍␊
Parameters
firmware_version
– Format: XX.XX.XXXX where the digits group are: major.minor.build version
SN?
Function
Permission
Transparency
Set:
-
-
-
Get:
SN?
End User
Public
Description
Syntax
Set:
-
-
Get:
Get device serial number
#SN?
␍
Response
~nn@
SN
␠
serial_number
␍␊
Parameters
serial_number
- 14 decimal digits, factory assigned