Installing on a Rack 

 

5  Installing on a Rack 

This section describes what to do before installing the 

VP-6xl

N

 

on a rack and 

how to rack mount. To rack-mount the 

VP-2xl

, see the Rack Adapters user 

manual for detailed instructions. 
 

Before Installing on a Rack 

Before installing on a rack, be sure that the environment is 

within the recommended range: 
Operating temperature range  +5 to +45 Deg. Centigrade 
Operating humidity range 

5 to 65 % RHL, non-condensing 

Storage temperature range 

-20 to +70 Deg. Centigrade 

Storage humidity range 

5 to 95% RHL, non-condensing 

 

 

 CAUTION!! 

When installing on a 19" rack, avoid hazards by taking 

care that: 
1

 

It is located within the recommended environmental 

conditions, as the operating ambient temperature of a 

closed or multi unit rack assembly may exceed the room 

ambient temperature. 

2

 

Once rack mounted, enough air will still flow around the 

machine. 

3

 

The machine is placed straight in the correct horizontal 

position. 

4

 

You do not overload the circuit(s). When connecting the 

machine to the supply circuit, overloading the circuits 

might have a detrimental effect on overcurrent 

protection and supply wiring. Refer to the appropriate 

nameplate ratings for information. For example, for fuse 

replacement, see the value printed on the product label. 

5

 

The machine is earthed (grounded) in a reliable way 

and is connected only to an electricity socket with 

grounding. Pay particular attention to supply 

connections other than direct connections to the branch 

circuit (for example, the use of power strips), and that 

you use only the power cord that is supplied with the 

machine.

 

 

 

 

 

 

 

 

 

How to Rack Mount 

To rack-mount the machine: 
1

 

Attach both ear brackets to the 

machine. To do so, remove the 

screws from each side of the 

machine (3 on each side), and 

replace those screws through 

the ear brackets. 

 

2

 

Place the ears of the machine 

against the rack rails, and insert 

the proper screws (not 

provided) through each of the 

four holes in the rack ears. 

Note that: 

 In some models, the front panel 

may feature built-in rack ears 

 Detachable rack ears can be 

removed for desktop use 

 Always mount the machine in the 

rack before you attach any cables or 

connect the machine to the power 

 If you are using a Kramer rack 

adapter kit (for a machine that is not 

19"), see the Rack Adapters user 

manual for installation instructions 

(you can download it at: 

http://www.kramerelectronics.com) 

 

Summary of Contents for VP-2XL

Page 1: ...Kramer Electronics Ltd USER MANUAL Models VP 2xl 1 2 VGA Distributor VP 6xlN 1 6 UXGA Distributor...

Page 2: ...tor Front and Rear View 3 Figure 2 VP 6xlN 1 6 UXGA Distributor Front and Rear View 4 Figure 3 Underside of the VP 6xlN 1 6 UXGA Distributor 5 Figure 4 Connecting the VP 2xl 1 2 VGA Distributor 7 Figu...

Page 3: ...graphics up to at least UXGA distribution to multiple monitors projectors Expanding and creating larger systems The package includes the following items VP 2xl 1 2 VGA Distributor2 or VP 6xlN 1 6 UXGA...

Page 4: ...tributor is a high performance computer graphics video amplifier for computer graphics video signals with resolutions ranging up to at least UXGA and is HDTV compatible It takes one input provides cor...

Page 5: ...urn to control the VGA XGA output level 4 AUDIO IN R L RCA Connectors Connect to the right and left audio source 5 VGA IN HD15F Connector Connect to the VGA XGA source AUDIO OUT 1 R L RCA Connectors C...

Page 6: ...KRAMER SIMPLE CREATIVE TECHNOLOGY Your Distributors 4 Figure 2 VP 6xlN 1 6 UXGA Distributor Front and Rear View...

Page 7: ...USE AC connector enabling power supply to the unit Figure 3 and Table 3 define the underside panel switches of the VP 6xlN ON ON OFF OFF ID Bit 11 ID Bit 4 Figure 3 Underside of the VP 6xlN 1 6 UXGA D...

Page 8: ...a detrimental effect on overcurrent protection and supply wiring Refer to the appropriate nameplate ratings for information For example for fuse replacement see the value printed on the product label...

Page 9: ...nnect the OUTPUT HD15F connectors to up to1 two acceptors for example a display and a projector and connect the R and L AUDIO OUT RCA connectors to audio acceptors for example two amplifiers with spea...

Page 10: ...pensation equalization level if required 5 Set the ID BIT switches 4 and 11 on the underside to ON by sliding them to the left This would enable a notebook or laptop if connected instead of a computer...

Page 11: ...DEO 77dB AUDIO 85dB DIMENSIONS 16 5cm x 12 cm x 4 5 cm 6 5 x 4 7 x 1 8 W D H POWER SOURCE 12VDC 100mA WEIGHT 0 7 kg 1 5 lbs approx ACCESSORIES Power supply OPTIONS VA 50P rack mountable power supply w...

Page 12: ...is required the original dated invoice or a copy must be presented as proof of warranty coverage and should be included in any shipment of the product Please also include in any mailing a contact name...

Page 13: ...or the latest information on our products and a list of Kramer distributors visit our Web site www kramerelectronics com where updates to this user manual may be found We welcome your questions commen...