12
VM-3UHD - Protocol 3000
7
Protocol 3000
The
VM-3UHD
can be operated using serial commands from a PC, remote
controller, or touch screen. The unit communicates using the default Kramer
Protocol 3000.
This section describes:
Kramer Protocol 3000 syntax (see
Kramer Protocol 3000 commands (see
7.1
Syntax
With Kramer Protocol 3000 you can control a device from any standard
terminal software (for example, the Windows® HyperTerminal Application) or
from TCP/UDP clients connected to default TCP port 5000 or UDP port 50000
(port numbers can been changed by the user). RS-232/RS-485
communications protocol uses a data rate of 115200 bps, no parity, 8 data
bits, and 1 stop bit.
7.1.1
Host Message Format
Start
Address (opt)
Body
Delimiter
#
Destination_id@
Message
CR
7.1.1.1
Simple Command
Command string with only one command without addressing:
Start
Body
Delimiter
#
Command SP
Parameter_1,Parameter_2,…
CR