RJ-45 Pinout:
DIP-Switch Settings
For the Ethernet connector, see the wiring diagram
below:
All DIP-switches are set to Off (up) by default.
Changes to DIP-switches 4 and 5, only take
effect after power cycling the device.
PIN EIA /TIA 568B
PIN Wire Color
#
Feature
Dip-switch Settings
1
Orange / White
1
Reserved
Set to OFF.
2
Orange
2
Compression
Level
OFF
– Low compression level is applied.
ON
– High compression level is applied to
gain better extension reach performance.
3
Green / White
4
Blue
5
Blue / White
3
Compressed
Signals
OFF
– Compression is applied only to signal
resolutions higher than 1080p.
ON
– Compression is applied to all signal
resolutions.
6
Green
7
Brown / White
8
Brown
Compression can be applied for a
TP-583T
/
TP-583R
paired-connection only, thus
preserving backward compatibility
with standard-HDBT extenders.
4, 5
FW Upgrade
OFF, OFF
– Normal operation mode.
ON, OFF
– HDBT FW upgrade mode.
ON, ON
– Compression FW upgrade mode.
When either DIP-switch is set to
ON, the device extension operation
is disabled.
6
IR Frequency
Mode
OFF (up)
– Frequency is 38kHz.
ON (down)
– Wide-range modulated IR
frequency.
For optimum range and performance use the
recommended Kramer cables available at
www.kramerav.com/product/TP-583T, TP-583R
Step 5: Connect the power
Connect the 12V DC power adapter to
TP-583T
/
TP-583R
and plug it into the mains electricity.
Safety Instructions
Caution:
There are no operator serviceable parts inside the unit.
Warning:
Use only the Kramer Electronics power adapter that is provided with the unit.
Warning:
Disconnect the power and unplug the unit from the wall before installing.
for updated safety information.
Step 6: Operate TP-583T/TP-583R
Operate
TP-583T
/
TP-583R
remotely, by RS-232 serial
commands transmitted by a touch
screen system, PC, or other serial
controller
RS-232 Control
Baud Rate:
57,600
Data Bits:
8
Stop Bits:
1
Parity:
None
Command Format: ASCII