background image

Using Your TP-300FW FireWire Range Extender 

 

connector on the second 

TP-300FW

 unit

1

3.  Be sure that the power on each FireWire device is turned ON. 

On each 

TP-300FW

 unit, the ACTIVE green LED lights indicating that a cable 

from an external powered and fully functioning FireWire device is connected. 

4.  On each 

TP-300FW

 unit, connect the 12V DC power adapter to the power 

socket and connect the adapter to the mains electricity. 
The red ON LED lights. 

5.2 

Connecting Three TP-300FW Units to Extend the Distance to 200m 

You can daisy-chain three 

TP-300FW

 units to extend the FireWire range to 200m.  

To connect three TP-300FW units (using straight pin-to-pin STP cables) to extend 
the FireWire distance to 200m, as illustrated in the example in 

Figure 3

                                                        

1 Alternatively, connect the CAT 5 CROSSED RJ-45 connector on the first TP-300FW unit to the CAT 5 CROSSED RJ-45 connector 

on the second TP-300FW unit 

Summary of Contents for TP-300FW

Page 1: ...Kramer Electronics Ltd USER MANUAL Model TP 300FW FireWire Range Extender...

Page 2: ...ding the Distance Between Two FireWire Devices to 100m 6 5 2 Connecting Three TP 300FW Units to Extend the Distance to 200m 7 6 Technical Specifications 9 Figures Figure 1 TP 300FW FireWire Range Exte...

Page 3: ...items TP 300FW FireWire Range Extender Power adapter 12V DC input This user manual2 2 Getting Started We recommend that you Unpack the equipment carefully and save the original box and packaging mater...

Page 4: ...KRAMER SIMPLE CREATIVE TECHNOLOGY Getting Started 2...

Page 5: ...ion from electrostatic discharge ESD 6 by suppressing all transient high voltages down to the allowed level In particular ESD protection for high speed data lines to IEC 61000 4 2 ESD 15kV air 8kV con...

Page 6: ...bles where possible since the compliance to electromagnetic interference has been tested using STP cables 3 2 Recommendations for Achieving the Best Performance To achieve the best performance Use onl...

Page 7: ...r powering the unit center pin positive 2 CAT 5 CROSSED RJ 45 Connector Connects to the CAT 5 STRAIGHT connector on another TP 300FW unit 3 CAT 5 STRAIGHT RJ 45 Connector Connects to the CAT 5 CROSSED...

Page 8: ...Distance Between Two FireWire Devices to 100m 1 Connect a FireWire device for example a video camcorder to the FW PORT on the first TP 300FW unit and a FireWire device for example a PC to the FW PORT...

Page 9: ...adapter to the power socket and connect the adapter to the mains electricity The red ON LED lights 5 2 Connecting Three TP 300FW Units to Extend the Distance to 200m You can daisy chain three TP 300F...

Page 10: ...AT 5 CROSSED RJ 45 connector on the second TP 300FW unit 3 Connect the CAT 5 STRAIGHT RJ 45 connector on the second TP 300FW unit to the CAT 5 CROSSED RJ 45 connector on the third TP 300FW unit1 4 Be...

Page 11: ...1 of the TP 300FW FireWire Range Extender PORT One 6 pin serial 1394 FireWire port 2 RJ 45 twisted pair ports TRANSFER RATE 100Mbps IEEE 1394 STANDARDS IEEE 1394a 2000 IEEE 1394 1995 IEEE 1394b 2002...

Page 12: ...KRAMER SIMPLE CREATIVE TECHNOLOGY 10...

Page 13: ...st information on our products and a list of Kramer distributors visit our Web site www kramerelectronics com where updates to this user manual may be found We welcome your questions comments and feed...

Reviews: