background image

KRAMER:  SIMPLE CREATIVE TECHNOLOGY

 

Overview 

Has a looping CAT 5 input that allows the expansion of systems

by daisy-chaining the receivers

Can power or be powered by the transmitter over the same CAT 5

cable

Can change the polarity of decoding H and V Sync for video

Includes EQ. and level controls

Is 12VDC fed

3.3  About the Power Connect™ Feature 

The Power Connect feature applies as long as the cable can carry power. 

This feature is available when using STP cable and the distance does not 

exceed 50m on standard CAT 5 cable. For longer distances, heavy gauge 

cable should be used

1

For a CAT 5 cable exceeding a distance of 50m, separate power supplies 

should be connected to the transmitter and to the receiver simultaneously. 

.

 

For units which are connected via RJ-45 connectors, 

make sure that the shield of the STP cable is connected to the metal casing 

of the connectors on both ends of the cable. For units which are connected 

via terminal block connectors, the shield of the STP cable must be 

connected to a ground terminal on the units at both ends (use the ground 

terminal of the power supply connection if necessary). 

3.4  Shielded Twisted Pair (STP)/Unshielded Twisted Pair (UTP) 

We recommend that you use Shielded Twisted Pair (STP) cable. There are 

different levels of STP cable available, and we advise you to use the best 

quality STP cable that you can afford. Our non-skew-free cable, Kramer 

BC-STP

 is intended for analog signals where skewing is not an issue. For 

cases where there is skewing, our UTP skew-free cable, Kramer 

BC-XTP

may be used. Bear in mind, though, that we advise using STP cables where 

possible, since the compliance to electromagnetic interference was tested 

using those cables. 
Although Unshielded Twisted Pair (UTP) cable might be preferred for long 

range applications, the UTP cable should be installed far away from electric 

cables, motors and so on, which are prone to create electrical interference.  

However, since the use of UTP cable might cause inconformity to 

electromagnetic standards, Kramer does not commit to meeting the standard 

with UTP cable. 

1 CAT 5 cable is still suitable for the video/audio transmission, but not for feeding the power at these distances 

Summary of Contents for TP-100AXR

Page 1: ...Kramer Electronics Ltd USER MANUAL Models TP 100AXR PC Audio Line Transmitter TP 200AXR PC Audio Line Receiver...

Page 2: ...7 5 Connecting the PC Audio Line Transmitter Receiver 8 5 1 Connecting a Transmitter Receiver Pair 8 5 2 Connecting Multiple Devices 10 5 3 Wiring the CAT 5 LINE IN LINE OUT RJ 45 Connectors 11 6 Tec...

Page 3: ...tion for schools hospitals security and stores The package includes one or more of the following TP 100AXR TP 200AXR Power supply 12V DC This user manual2 2 Getting Started We recommend that you Unpac...

Page 4: ...KRAMER SIMPLE CREATIVE TECHNOLOGY Getting Started 2 2 1 Quick Start The quick start charts summarize the basic setup and operation steps of the TP 100AXR TP 200AXR...

Page 5: ...serving the quality of the audio signal In particular the TP 100AXR features Resolution up to and including WUXGA HDTV compatibility Looping inputs that allow connection of a local display and audio a...

Page 6: ...st be connected to a ground terminal on the units at both ends use the ground terminal of the power supply connection if necessary 3 4 Shielded Twisted Pair STP Unshielded Twisted Pair UTP We recommen...

Page 7: ...cables1 Avoid interference from neighboring electrical appliances that may adversely influence signal quality and position your Kramer product away from moisture excessive sunlight and dust to avoid i...

Page 8: ...n receiving power 2 PC IN 15 pin HD F Connector Connects to the PC source 3 PC LOOP OUT 15 pin HD F Connector Connects to a computer graphics acceptor 4 LINE OUT 1 RJ 45 Connector Connects to 1 5 the...

Page 9: ...ts to 3 another TP 200AXR 9 TERMINATION PC UXGA Pushbutton Press IN to terminate the PC UXGA connection 10 TERMINATION S PDIF Pushbutton Press IN to terminate the S PDIF connection 11 STEREO AUDIO OUT...

Page 10: ...he LINE IN RJ 45 connector on the TP 200AXR via UTP cabling the range can exceed 300ft 100m see section 5 3 4 Connect the 12V DC power adapters to the power sockets4 and connect the adapters to the ma...

Page 11: ...Connecting the PC Audio Line Transmitter Receiver 9 Figure 3 Connecting the PC Audio Line Transmitter Receiver System...

Page 12: ...ion pushbuttons Do not terminate the devices in the middle of the line 6 A similar chain can be connected to the LINE OUT 2 RJ 45 connector on the TP 100AXR 7 Connect the 12V DC power adapters to the...

Page 13: ...connectors 5 Table 3 CAT 5 PINOUT Figure 5 CAT 5 PINOUT 36 78 12 5 4 1 45 78 6 3 2 EIA TIA 568A EIA TIA 568B PIN Wire Color PIN Wire Color 1 Green White 1 Orange White 2 Green 2 Orange 3 Orange White...

Page 14: ...mm mini jack 1 RJ 45 line loop out 2 VGA on 15 pin HD connectors 2 S PDIF on RCA connectors 2 audio analog 3 5mm mini jacks MAX OUTPUT LEVEL Video 1 8V audio 2 9V CONTROLS Level 7dB to 4dB EQ 0dB to 1...

Page 15: ...heractsofnature ii Product modification orfailureto followinstructions supplied with theproduct iii Repairorattemptedrepairby anyonenot authorized byKramer iv Anyshipment oftheproduct claims must bepr...

Page 16: ...our products and a list of Kramer distributors visit our Web site where updates to this user manual may be found We welcome your questions comments and feedback Caution Safety Warning Disconnect the...

Reviews: