SP-4D - Operating the SP-4D
6
Operating the SP-4D
This section explains how to use the:
•
LCD display (see
Section 6.1
)
•
Front panel buttons (see
Section 6.2
)
•
LED indicators (see
Section 6.3
)
6.1
Using the LCD Display
The
SP-4D
includes a two-line, 20-character per line LCD display that displays
(while in the main mode of operation) the machine status, the genlock reference
source and standard of video signals on all four SDI outputs. The following
examples explain what is shown on the display.
1. When the genlock mode is turned OFF, the display shows:
SET3 INT.XTAL REF.
OutpForced: 720p/60
This means the setup (preset) number is 3; the internal crystal generator
XTAL is used as the genlock reference source, the standard of output signals
on all four outputs is forced to 720p/60.
2. If the genlock is turned ON and a reference input signal was selected as
dedicated input GenlockIN, the display shows:
SET3 Ref: GenlockIN
OutpForced: 720p/60
3. If the output standard selection mode is AUTO, the display shows:
SET3 Ref: GenlockIN
OutputAuto: 720p/60
4. If genlock is turned ON and SDI input channel 2 is selected as the reference
input signal, the display shows:
SET3 RefSource: IN2
OutpForced: 720p/60