background image

 

RC-76M

RC-712M - Getting Started 

 

Getting Started 

We recommend that you: 

 

Unpack the equipment carefully and save the original box and packaging 

materials for possible future shipment 

 

Review the contents of this user manual 

 

 

 

2.1 

Achieving the Best Performance 

To achieve the best performance: 

 

Use only good quality connection cables (we recommend Kramer high-

performance, high-resolution cables) to avoid interference, deterioration in 

signal quality due to poor matching, and elevated noise levels (often 

associated with low quality cables) 

 

Do not secure the cables in tight bundles or roll the slack into tight coils 

 

Avoid interference from neighboring electrical appliances that may adversely 

influence signal quality  

 

Position your Kramer 

RC-76M/RC-712M 

away from moisture, excessive 

sunlight and dust 

 

 

 

This equipment is to be used only inside a building. It may only be 

connected to other equipment that is installed inside a building. 

 
 
 
 
 
 
 
 
 

i

!

Summary of Contents for RC-712M

Page 1: ...KRAMER ELECTRONICS LTD USER MANUAL MODEL RC 76M RC 712M P N 2900 300329 Rev 3...

Page 2: ......

Page 3: ...12 5 Operating the RC 76M RC 712M 16 6 Front Panel Button Labels 17 7 Technical Specifications 20 Figures Figure 1 RC 76M RC 712M Room Controller Front Panel 5 Figure 2 RC 76M RC 712M Room Controllers...

Page 4: ...11 groups that are clearly defined by function GROUP 1 Distribution Amplifiers GROUP 2 Switchers and Routers GROUP 3 Control Systems GROUP 4 Format Standards Converters GROUP 5 Range Extenders and Re...

Page 5: ...ce high resolution cables to avoid interference deterioration in signal quality due to poor matching and elevated noise levels often associated with low quality cables Do not secure the cables in tigh...

Page 6: ...al and Electronic Equipment WEEE Directive 2002 96 EC aims to reduce the amount of WEEE sent for disposal to landfill or incineration by requiring it to be collected and recycled To comply with the WE...

Page 7: ...hes LEDs or relays Kramer Site CTRL compatibility for network remote control and management over the Ethernet port 2 bidirectional RS 232 ports for the control of AV equipment such as projectors LCD a...

Page 8: ...Button function is programmed by the K Config Configuration software 2 IR In Built in IR Receiver Use to learn the IR commands from a machine s remote control transmitter 3 USB Connector Connect to a...

Page 9: ...IO GND Terminal Block Connector Connect to various sensors switches LEDs or relays 10 IR 2 Terminal Block Connector Connect to IR emitter cable 2 11 IR 1 Terminal Block Connector Connect to IR emitter...

Page 10: ...number 192 168 1 39 Mask 255 255 0 0 Gateway 0 0 0 0 First disconnect the power supply and then connect it again while pressing the Reset button The unit powers up and loads its memory with the factor...

Page 11: ...he Ports The following diagrams illustrate a compatible 2 gang on wall box but installation is similar with any compatible wall box We recommend that you first detach the male connectors from the rear...

Page 12: ...en switch on the power to each device Although the illustration in Figure 4 shows the RC 712M the following example applies also to the RC 76M To connect the RC 76M RC 712M as illustrated in the examp...

Page 13: ...5 Connect the Ethernet port to a network Figure 4 Connecting the RC 712M 4 2 1 1 Connecting RS 232 Devices You can control up to two AV devices such as a projector or an RS 232 display by connecting...

Page 14: ...the line slide the RS 485 termination switch up otherwise make sure it is set to down see Figure 1 4 3 Connecting the Ethernet Port The Ethernet connection of the RC 76M RC 712M lets you perform all...

Page 15: ...5 Mounting the RC 76M RC 712M onto the Merten Housing After the cables are connected you can mount the device onto the housing Note that the illustrations in this section do not show the cables that...

Page 16: ...re the unit to the housing by screwing the four 3 5x10 conical Philips screws supplied with the unit into their 4 designated holes see Figure 7 Figure 7 Securing the RC 76M RC 712M 4 Mount the frame o...

Page 17: ...9 Figure 9 Button Cap Orientation with Label 6 Retaining this orientation place each button cap with the label to its correct button see Figure 10 Figure 10 Placing the Button Caps and Mounting the D...

Page 18: ...6 screws with Allen key supplied to fix the faceplates and the frame to the housing see Figure 12 Note that if you need to reconfigure the buttons simply remove these two screws and remove the frame a...

Page 19: ...712M You can operate your RC 76M RC 712M via the front panel buttons or remotely by AUX keypad over K NET The front panel buttons are configured using the K Config software For instructions on using...

Page 20: ...M Front Panel Button Labels 17 6 Front Panel Button Labels The RC 76M RC 712M are supplied with a button label sheet and 6 8 clear button caps to house the labels Figure 13 illustrates a sample button...

Page 21: ...18 RC 76M RC 712M Front Panel Button Labels...

Page 22: ...RC 76M RC 712M Front Panel Button Labels 19 Figure 13 Sample Button Label Sheet...

Page 23: ...IP number 192 168 1 39 Mask 255 255 0 0 Gateway 0 0 0 0 POWER CONSUMPTION 12V DC 1 25A OPERATING TEMPERATURE 0 to 40 C 32 to 104 F STORAGE TEMPERATURE 40 to 70 C 40 to 158 F HUMIDITY 10 to 90 RHL non...

Page 24: ......

Page 25: ...n on our products and a list of Kramer distributors visit our Web site where updates to this user manual may be found P N 2900 300329 Rev 3 SAFETY WARNING Disconnect the unit from the power supply bef...

Reviews: