Feature
Function
1
2 LCD Labels
Display the name of each button group; programmed via the
K-Config
configuration software
2
6 Configurable Buttons
Programmed for distinct functions via the
K-Config
configuration software
3
Max volume LED
Lights red to indicate maximum volume
4
Volume level LEDs
Light according to the volume level
5
K-NET2 Connector
Connects to the Ground, RS-485 communication, and power supply
Note
: The Ground is sometimes connected to the shield of the RS-485 cable.
6
K-NET1 Connector
7
RS-232 Port (GND, Rx,
Tx)
Connects to A/V equipment, PC or serial controller
8
IR Port
Controls a device via an IR Emitter
9
RELAY Ports
Connect to room items such as lighting and screen settings
10
Grounding Screw
Connects to grounding wire (optional)
11
PROGRAM (USB)
Connector
Connects to a computer for system configuration, firmware upgrade, or setting the K-NET ID no.
12
IR IN built-in IR
Receiver
Used to learn the IR commands from a machine’s remote control transmitter.
13
PROG Switch
For technical support use only.
Note
: Should be set in the direction of the arrow for normal operation.
14
K-NET TERM Switch
Controls K-NET bus termination:
•
Push the switch in the direction of the arrow to terminate.
•
Push the switch away from the direction of the arrow to leave unterminated.
Note
: The last physical device on a K-NET bus must be terminated.
To access the K-NET termination switch, insert a small screwdriver into the gap between the rear panel PCB and
the metal rear panel cover.
15
RESET TO DEFAULT
Button
To reset memory to the factory default K-NET ID auxiliary setting (ID=2), disconnect the power and then reconnect it
while using a small screwdriver to press the RESET TO DEFAULT button.
Note
: This operation should be carried out by authorized Kramer technical personnel or by a qualified system
integrator.
To access the RESET TO DEFAULT button, insert a small screwdriver into the gap between the rear panel PCB
and the metal rear panel cover.
Step 3: Connect inputs and outputs
Always switch OFF the power on each device before connecting it to your
RC-63DLN
.
1. Connect the inputs and outputs to their appropriate devices
using terminal block connectors (see example on the right):
▪
I/O ports: 1 RS-232, 2 K-NET
▪
Outputs: 1 infrared, 2 relays
2. Connect 12V DC power to the unit if power is not available
over the K-NET.
3. Mount the unit in a wall.
To achieve specified extension distances, use the recommended Kramer
cables available at
www.kramerav.com/product/RC-63DLN
Using third-party cables may cause damage!
Step 4: Connect power
Connect the power cord to
RC-63DLN
and plug it into the mains electricity.
Safety Instructions (See
for updated safety information)
Caution:
•
For products with relay terminals and GPI\O ports, please refer to the permitted rating for an external connection, located next to the terminal or in the User Manual.
•
There are no operator serviceable parts inside the unit.
Warning:
•
Use only the power cord that is supplied with the unit.
•
Disconnect the power and unplug the unit from the wall before installing.
Step 5: Operate RC-63DLN
Operate the unit via the front panel buttons or remotely by AUX. keypad over K-NET.
Note
: By default, the
RC-63DLN
is set up as an auxiliary device.
Configure and customize the
RC-63DLN
•
Configure the unit using
K-Config
www.kramerav.com/support/product_downloads.asp
•
Customize the buttons by inserting the appropriate labels under the button caps.