Kramer RC-63DLN Quick Start Manual Download Page 2

 

 

Feature 

Function 

2 LCD Labels 

Display the name of each button group; programmed via the 

K-Config

 configuration software 

6 Configurable Buttons 

 

Programmed for distinct functions via the 

K-Config

 configuration software 

Max volume LED 

Lights red to indicate maximum volume 

Volume level LEDs 

Light according to the volume level 

K-NET2 Connector 

Connects to the Ground, RS-485 communication, and power supply 

Note

: The Ground  is sometimes connected to the shield of the RS-485 cable. 

K-NET1 Connector 

RS-232 Port (GND, Rx, 
Tx) 

Connects to A/V equipment, PC or serial controller 

IR Port 

Controls a device via an IR Emitter 

RELAY Ports  

Connect to room items such as lighting and screen settings 

10 

Grounding Screw 

Connects to grounding wire (optional) 

11 

PROGRAM (USB) 
Connector 

Connects to a computer for system configuration, firmware upgrade, or setting the K-NET ID no. 

12 

IR IN built-in IR 
Receiver 

Used to learn the IR commands from a machine’s remote control transmitter. 

13 

PROG Switch 

For technical support use only. 

Note

: Should be set in the direction of the arrow for normal operation. 

14 

K-NET TERM Switch 

Controls K-NET bus termination: 

 

Push the switch in the direction of the arrow to terminate. 

 

Push the switch away from the direction of the arrow to leave unterminated. 

Note

: The last physical device on a K-NET bus must be terminated. 

To access the K-NET termination switch, insert a small screwdriver into the gap between the rear panel PCB and 
the metal rear panel cover. 

15 

RESET TO DEFAULT 
Button 

To reset memory to the factory default K-NET ID auxiliary setting (ID=2), disconnect the power and then reconnect it 
while using a small screwdriver to press the RESET TO DEFAULT button.  

Note

: This operation should be carried out by authorized Kramer technical personnel or by a qualified system 

integrator. 
To access the RESET TO DEFAULT button, insert a small screwdriver into the gap between the rear panel PCB 
and the metal rear panel cover. 

 

Step 3:  Connect inputs and outputs 

Always switch OFF the power on each device before connecting it to your 

RC-63DLN

1.  Connect the inputs and outputs to their appropriate devices 

using terminal block connectors (see example on the right): 

 

I/O ports: 1 RS-232, 2 K-NET 

 

Outputs: 1 infrared, 2 relays 

2.  Connect 12V DC power to the unit if power is not available 

over the K-NET. 

3.  Mount the unit in a wall.  

 

 

 

To achieve specified extension distances, use the recommended Kramer 

cables available at 

www.kramerav.com/product/RC-63DLN

. 

Using third-party cables may cause damage! 

Step 4:  Connect power 

Connect the power cord to 

RC-63DLN

 and plug it into the mains electricity. 

 

Safety Instructions (Se

www.kramerav.com

 for updated safety information)

 

 

Caution: 

  For products with relay terminals and GPI\O ports, please refer to the permitted rating for an external connection, located next to the terminal or in the User Manual. 

  There are no operator serviceable parts inside the unit. 

Warning: 

  Use only the power cord that is supplied with the unit.  

  Disconnect the power and unplug the unit from the wall before installing.

  

Step 5:  Operate RC-63DLN 

Operate the unit via the front panel buttons or remotely by AUX. keypad over K-NET. 

Note

: By default, the 

RC-63DLN

 is set up as an auxiliary device. 

Configure and customize the 

RC-63DLN

 

 

Configure the unit using 

K-Config

 software, available at 

www.kramerav.com/support/product_downloads.asp

. 

 

Customize the buttons by inserting the appropriate labels under the button caps. 

  

  