RC-43SL - Overview

 

 

3.1 

Defining the RC-43SL 6-Button Room Controller 

This section defines the 

RC-43SL

 

Figure 1: RC-43SL 6-Button Room Controller 

Feature 

Function 

Six Touch-sensitive Buttons 

Program button functions on the connected 
room controller 

Six LEDs  

Flash yellow when the button is touched. Each 
LED can be custom programmed to light on 
specific actions  

Ground Terminal Connector 

Connects to ground to earth the device 

USB

 Connector 

Connects to a computer for unit configuration 
and firmware upgrading 

ETHERNET

 RJ-45 Connector 

Connects to the PC or other LAN device 
through a networking LAN 

IR OUT

 Terminal Blocks 

Connect to IR emitter cables (from 1 to 2) 

FACTORY DEFAULT

 Button 

Using a small screwdriver, press to perform a 
factory reset 

IR IN

 Sensor 

Used for IR learning 

K-NET

 Terminal Block 

PIN +12V is for powering this (and another) 
unit, PIN A (+) PIN and PIN B (-) are for 
RS-485, PIN GND is for the ground connection 

The ground connection is sometimes connected to the 
shield of the RS-485 cable 

To supply 12V to another device, connect its 12V power 
line to the +12V DC terminal of this device 

10 

RS-232

 Terminal Blocks 

Connect to the RS-232 devices (from 1 to 2) 

11 

RELAYS

 Terminal Blocks 

Connect to low-voltage relay-driven devices 
(from 1 to 3) 

 

Summary of Contents for RC-43SL

Page 1: ...USER MANUAL MODEL RC 43SL 6 Button Room Controller P N 2900 300450 Rev 1 www kramerAV com...

Page 2: ......

Page 3: ......

Page 4: ...ng the RS 232 Port 7 4 2 Connecting the Ethernet Port 8 4 3 Connecting the K NET Port 8 4 4 Installing the Front Panel Buttons 9 4 5 Installing the RC 43SL in the Wall Mounting Box 10 5 Configuring th...

Page 5: ...efined by function GROUP 1 Distribution Amplifiers GROUP 2 Switchers and Routers GROUP 3 Control Systems GROUP 4 Format Standards Converters GROUP 5 Range Extenders and Repeaters GROUP 6 Specialty AV...

Page 6: ...ference deterioration in signal quality due to poor matching and elevated noise levels often associated with low quality cables Do not secure the cables in tight bundles or roll the slack into tight c...

Page 7: ...ected and recycled To comply with the WEEE Directive Kramer Electronics has made arrangements with the European Advanced Recycling Network EARN and will cover any costs of treatment recycling and reco...

Page 8: ...dual actions The RC 43SL features 6 touch sensitive backlit buttons with indicator LEDs 2 bidirectional RS 232 ports to control AV equipment such as projectors LCD and PDP displays power amplifiers sw...

Page 9: ...45 Connector Connects to the PC or other LAN device through a networking LAN 6 IR OUT Terminal Blocks Connect to IR emitter cables from 1 to 2 7 FACTORY DEFAULT Button Using a small screwdriver press...

Page 10: ...To connect the RC 43SL as illustrated in the example in Figure 2 1 Connect the RELAY terminal block connectors as follows Connect RELAY 1 and 2 to blinds Connect RELAY 3 to a screen 2 Connect the IR...

Page 11: ...ton Room Controller 4 1 Connecting the RS 232 Port To connect an AV device to the RC 43SL connect the RS 232 9 pin D sub port on your device to the RS 232 terminal block on the rear panel of the RC 43...

Page 12: ...to the Ethernet port on a network hub or network router via a straight cable with RJ 45 connectors 2 Over the network connect to a PC running Site CTRL After connecting the Ethernet port you have to i...

Page 13: ...plate by carefully prying it away from the printed circuit board PCB frame using a small screwdriver being careful not to damage it 2 Remove the stock buttons from the front panel 3 Insert the button...

Page 14: ...g Box Figure 5 Mounting the RC 43SL in a Wall Box To install the RC 43SL in the wall mounting box 1 Remove the cover plate of the RC 43SL 2 Insert the RC 43SL into the wall mounting box and secure it...

Page 15: ...ing the RC 43SL 11 5 Configuring the RC 43SL Configure the unit using Kramer K Config configuration software Download the software from the Kramer Web site http www kramerelectronics com support produ...

Page 16: ...32 to 104 F STORAGE TEMPERATURE 40 to 70 C 40 to 158 F HUMIDITY 10 to 90 RHL non condensing DIMENSIONS 6 9cm x 3 9cm x 11 4cm 2 7 x 1 5 x 4 5 W D H WEIGHT 0 1 kg 0 22lb SHIPPING DIMENSIONS 6 9cm x 1...

Page 17: ......

Page 18: ...re opening andservicing For the latest information on our products and a list of Kramer distributors visit our Web site to find updates to this user manual We welcome your questions comments and feedb...

Reviews: