Step 4:  Connect the inputs and outputs 

Always switch OFF the power on each device before connecting it to your 

RC-308

. For best results, we recommend that you always 

use Kramer high-performance cables to connect AV equipment to 

RC-308

 

 

Step 5:  Install RC-308 

After connecting the ports, insert the device into the in-wall box and connect the parts as shown in the illustrations below: 

European Version 

US Version 

 

 

We recommend that you use any of the following standard 1 Gang in-wall junction boxes: 

 

US

: 1 Gang US electrical junction boxes. 

 

EU

: 1 Gang in-wall junction box, 47mm minimum depth (DIN 49073). 

 

UK

: 1 Gang in-wall junction box, 75x75mm, 47mm depth (BS 4662). 

 

Summary of Contents for RC-308

Page 1: ...rting the button labels 3 Mounting Screw Holes For securing the frame to the wall US version only 4 Configurable RGB Backlit Buttons 8 Configured to control the room and A V devices Remove button covers to insert button labels included 5 Mounting Bracket For fixing the frame to the in wall box 6 DIP Switches For K NET The last physical device on a K NET bus must be terminated For RS 485 The first ...

Page 2: ...e connected unit 15 Factory Reset Button Press while connecting the power and then release to reset the device to its default parameters To access this button you need to remove the Button Faceplate 16 Mini USB Type B Port Connect to your PC for firmware upgrade or for uploading the configuration To access the USB port you need to remove the Button Faceplate 17 IR Sensor For learning commands from...

Page 3: ...o RC 308 Step 5 Install RC 308 After connecting the ports insert the device into the in wall box and connect the parts as shown in the illustrations below European Version US Version We recommend that you use any of the following standard 1 Gang in wall junction boxes US 1 Gang US electrical junction boxes EU 1 Gang in wall junction box 47mm minimum depth DIN 49073 UK 1 Gang in wall junction box 7...

Page 4: ...for device configuration control and firmware upgrade Default IP Settings DHCP Enabled In order to connect to the RC 308 on first installation you need to identify the IP address that has been automatically assigned to the RC 308 Power Consumption 12V DC 780mA Source PoE or 12V DC 2A with open DC head Cooling Convection Ventilation Environmental Conditions Operating Temperature 0 to 40 C 32 to 104...

Reviews: