Kramer FC-28 Quick Start Manual Download Page 2

 

 

Step 3:  Mount FC-28 

Install 

FC-28

 using one of the following methods: 

  Attach the rubber feet and place the unit on a flat surface. 

  Fasten a bracket (included) on each side of the unit and attach it to a flat surface 

(see 

www.kramerav.com/downloads/FC-28

). 

 

  Mount the unit in a rack using the recommended rack adapter  

(see 

www.kramerav.com/product/FC-28

). 

 

  Ensure that the environment (e.g., maximum ambient temperature & 

air flow) is compatible for the device. 

  Avoid uneven mechanical loading. 

  Appropriate consideration of equipment nameplate ratings should be 

used for avoiding overloading of the circuits. 

  Reliable earthing of rack-mounted equipment should be maintained. 

 

Step 4:  Connect inputs and outputs 

Always switch OFF the power on each device before connecting it to your 

FC-28

 

 

 

To achieve specified extension distances, use the recommended Kramer cables available a

www.kramerav.com/product/FC-28

Using third-party cables may cause damage! 

Step 5:  Connect power 

If 

FC-28

 does not receive power via PoE, connect the power adapter to the 

FC-28

 and plug the power adapter it into the 

mains electricity. 

 

Safety Instructions (Se

www.kramerav.com

 for updated safety information)

 

 

Caution: 

  For products with relay terminals and GPI\O ports, please refer to the permitted rating for an external connection, located next to the 

terminal or in the User Manual. 

  There are no operator serviceable parts inside the unit. 

Warning: 

  Use only the power cord that is supplied with the unit.  

  Disconnect the power and unplug the unit from the wall before installing.

  

 

Step 6:  Operate FC-28 

 

The 

FC-28

 

is dispatched from the factory with the DHCP enabled and a random IP address. This means that if the device is 

connected to a LAN, you must identify the IP address of the 

FC-28

 

in order to connect to it. This can be done by using 

K-LAN Configurator to discover the IP address of the 

FC-28

. This is available for download from our website at 

www.kramerav.com

. 

To browse the 

FC-28

 

Web pages; upon taking the device out of the box, use the default host name “FC-26-xxxx”, where 

xxxx are the last four digits of the serial number of the device. 

 

To reset 

FC-28

 to its factory default settings: 

1.  Turn off the power to the device. 

2.  Press and hold the Reset button on the front panel. 

3.  Turn on the power to the device while holding down the 

Reset button for a few seconds. 

4.  Release the button. 

 

The device is reset to the factory default settings. 

 If you perform a factory reset, DHCP is disabled and the IP 

address of the device is set to 192.168.1.39. 

To configure and operate the 

FC-28

1.  Using the embedded Web pages, configure the Ethernet 

controller: 

  Set DHCP or assign a static IP address 

  Associate IP port(s) with serial port(s) 

  Configure the serial port parameters 

2.  Configure virtual port(s) on the K-Touch control device/PC. 

3.  Configure Ethernet connection(s) on the K-Touch control 

device/PC. 

4.  Switch port(s) on the Ethernet Controller. 

 

  

  

  

  

  