background image

 

 

 

Step 3: Install the FC-17 

Install 

FC-17

 using one of the following methods: 

  Attach the rubber feet and place the unit on a flat surface. 

  Fasten a bracket (included) on each side of the unit and attach it to a flat surface. 

For more information go to 

www.kramerav.com/downloads/FC-17

  Mount the unit in a rack using an optional 

RK-3T

 rack adapter. 

 

 

Step 4: Connect the inputs and outputs 

Always switch OFF the power on each device before connecting it to your 

FC-17

. For best results, we recommend that you always 

use Kramer high-performance cables to connect AV equipment to the 

FC-17

 

 

Set the DIP-switches: 

DIP-Switch # 

Description 

 

EDID 

DIP 1 (INT) 

When set to ON (down), the source sees the built-in default EDID 

 

DIP 2 (EXT) 

When set to ON (down), the source sees the EDID of the sink connected to 
the output 

 

DIP 3 (USER) 

When set to ON (down), the source sees the EDID programmed by the user 

Note

: For normal operation, set only one of the above three EDID DIP-switches to ON (down) 

Sampling 

DIP 4  
(YPbPr, 4:2:0) 

When set to ON (down): 4K50/60 YPbPr 4:4:4 and 4K50/60 RGB signals 
are converted to YPbPr 4:2:0; other resolutions are bypassed. 

When set to OFF (up): The signal is always bypassed 

 

Step 5: Connect the power 

Connect the 5V DC power adapter to the power socket and then connect the adapter to the mains electricity.

Safety Instructions 

 

Caution: 

There are no operator serviceable parts inside the unit.

 

Warning: 

Use only the Kramer Electronics power supply that is provided with the unit. 

Warning: 

Disconnect the power and unplug the unit from the wall before installing. 

See 

www.KramerAV.com

 for updated safety information. 

 

Step 6: Manage the EDID 

The EDID is managed via the EDID DIP-switches and the EDID management software. 

After downloading the EDID Manager software, connect the USB port 
from the 

FC-17

 to your PC and manage the EDID via the software: 

 

Set the acceptor EDID as the User EDID via 
the DIP-switches

1.  Disconnect the power. 

2.  Connect the acceptor to the 

FC-17

’s output. 

3.  Set DIP 1, DIP 2 and DIP 3 to ON. 

4.  Connect the power.  

All the LEDs flash briefly. 

5.  Disconnect the power, and set one of the INT, 

EXT or USER DIP-switches to ON, as desired. 

6.  Connect the power. 

 

Reviews: