Step 4: Connect the inputs and outputs
Always switch OFF the power on each device before connecting it to your
FC-101NET
. For best results, we recommend that you
always use Kramer high-performance cables to connect AV equipment to
FC-101NET
.
Step 5: Connect the power
Once connected, PoE is provided via the Dante port.
Safety Instructions
Caution:
There are no operator serviceable parts inside the unit.
Warning:
Disconnect the power before installing.
See
for updated safety information.
Step 6: Operate FC-101NET
Operate
FC-101NET
via:
Remotely, RS-232 serial
commands transmitted by a touch
screen system, PC, or other serial
controller.
RS-232
Baud Rate:
115200
Parity:
None
Stop Bits:
1
Data Bits:
8
Command Format: ASCII
Example: (set the volume output to -6dB): #AUD-LVL 2,1,-6<CR>
Technical Specifications
Outputs
1 Balanced Stereo Audio/2 Mono Audio
On a 5-pin terminal block
Port
1 Dante
On an RJ-45 connector
Control
Dante IP control matrix and Kramer Protocol 3000
Power
Consumption
48V DC, 100mA
Source
48V DC (PoE)
Cooling
Convection Ventilation
Environmental Conditions
Operating Temperature
0° to +40°C (32° to 104°F)
Storage Temperature
-40° to +70°C (-40° to 158°F)
Humidity
10% to 90%, RHL non-condensing
Regulatory Compliance
Safety
CE
Environmental
RoHs, WEEE
Enclosure
Size
Pico TOOL
Type
Aluminum
General
Net Dimensions (W, D, H)
6.2cm x 5.2cm x 2.4cm (2.4
” x 2” x 1”) W, D, H
Shipping Dimensions (W, D, H)
15.7 cm x 12cm x 8.7cm (6.2
” x 4.7” x 3.4”) W, D, H
Net Weight
0.08kg (0.2lb)
Shipping Weight
0.23kg (0.5lb)
Accessories
Included
Bracket set, double-sided adhesive dual lock tape
Optional
RK-4PT rack adapter
Specifications are subject to change without notice at