background image

KRAMER:  SIMPLE CREATIVE TECHNOLOGY

 

Operating the VS-44HDxl 

  

   

 

20 

7.1.2 

Switch OUT-IN Combinations in the Dual-Link Mode 

To switch an input to an output in the dual-link mode, via the front panel 

buttons

1

, in the AT ONCE mode (see section 7.2), do the following: 

1.  Press an OUTPUT button (either 1, 2 or ALL). 

The selected OUTPUT button illuminates brightly, as does the 7-segment 

display. 

2.  Press an INPUT button (either 1, 2 or OFF)

2

The selected input switches to the selected output, and that input button 

illuminates brightly. The digits displayed in the 7-segment display change 

as appropriate. 

7.2  Confirming Settings 

Choose to work in the AT ONCE or the CONFIRM mode (see section 7.2.1). 

When the 

VS-44HDxl

 operates in the AT ONCE mode, pressing an

 

OUT-IN 

combination implements the switch immediately. In the CONFIRM mode, the 

TAKE button must be pressed to authorize the switch. 
In the AT ONCE mode, you save time as execution is immediate and actions 

require no user confirmation. However, no protection is offered against changing 

an action in error. 
In the CONFIRM mode: 

 

You can key-in several actions and then confirm them by pressing the 

“ TAKE” button to simultaneously activate the multiple switches 

 

Every action requires user confirmation, protecting against erroneous 

switching 

 

Execution is delayed until the user confirms the action 

Note that after ten seconds the 

VS-44HDxl

 will go to standby mode and the 

buttons and the 7-segment display will illuminate less brightly. 

7.2.1 

Toggling between the AT ONCE and CONFIRM Modes 

To toggle between the AT ONCE and CONFIRM modes, do the following: 
1.  Press the dim TAKE button to toggle from the AT ONCE mode (in which 

the TAKE button is dim) to the CONFIRM mode (in which the TAKE 

button illuminates). 

Actions now require user confirmation and the TAKE button illuminates. 

2.  Press the illuminated TAKE button to toggle from the CONFIRM mode 

back to the AT ONCE mode. 

                                                        

1 For details of how to route an input to an output using the REMOTE connector, see section 6.9 
2 For immediate switching 

Summary of Contents for 21-70686010

Page 1: ...Kramer Electronics Ltd USER MANUAL Model VS 44HDxl 3G HD SD SDI 4x4 Matrix Switcher...

Page 2: ...1 Connecting the ETHERNET Port directly to a PC Crossover Cable 16 6 8 2 Connecting the ETHERNET Port via a Network Hub Straight Through Cable 18 6 8 3 Configuring the Ethernet Port 18 6 9 Controlling...

Page 3: ...a RS 485 for example using an RC 3000 15 Figure 7 Local Area Connection Properties Window 17 Figure 8 Internet Protocol TCP IP Properties Window 17 Figure 9 Using the REMOTE Connector 18 Tables Table...

Page 4: ...nfrared remote control transmitter and power cord This user manual2 2 Getting Started We recommend that you Unpack the equipment carefully and save the original box and packaging materials for possibl...

Page 5: ...KRAMER SIMPLE CREATIVE TECHNOLOGY Getting Started 2...

Page 6: ...erent colors green when the VS 44HDxl detects a standard definition signal or blue when it detects a high definition signal Features the ability to switch genlocked video signals according to timing o...

Page 7: ...uality due to poor matching and elevated noise levels often associated with low quality cables Avoid interference from neighboring electrical appliances that may adversely influence signal quality and...

Page 8: ...Your VS 44HDxl 3G HD SD SDI 4x4 Matrix Switcher 5 Figure 1 VS 44HDxl 3G HD SD SDI 4x4 Matrix Switcher...

Page 9: ...tween the CONFIRM mode 3 and the AT ONCE mode user confirmation per action is unnecessary When in CONFIRM mode the TAKE button implements a pending operation4 7 RCL RECALL Button Pressing the RCL butt...

Page 10: ...remote controller instead of using the front panel IR receiver 5 24 ETHERNET Connector Connects to the PC or other Serial Controller through computer networking 25 Power Connector with Fuse AC connect...

Page 11: ...er to the appropriate nameplate ratings for information For example for fuse replacement see the value printed on the product label 5 The machine is earthed grounded in a reliable way and is connected...

Page 12: ...tion 6 3 4 If required3 connect A Genlock source to the GENLOCK BNC connector The LOOP BNC connector to the GENLOCK connector of the next unit in the line and release the TERM button for looping4 5 Co...

Page 13: ...KRAMER SIMPLE CREATIVE TECHNOLOGY Connecting Your VS 44HDxl 3G HD SD SDI 4x4 Matrix Switcher 10 Figure 2 Connecting the VS 44HDxl 3G HD SD SDI 4x4 Matrix Switcher...

Page 14: ...SDI mixer 3 Set the dipswitches see section 6 2 4 If required3 connect A Genlock source to the GENLOCK BNC connector The LOOP BNC connector to the GENLOCK connector of the next unit in the line and re...

Page 15: ...he VS 44HDxl to work in the dual link mode as follows To switch to the dual link mode press and hold the OFF front panel button for 3 seconds until a red dot illuminates on the display on the second s...

Page 16: ...ontrolled when several VS 44HDxl units connect to a PC or serial controller Set the Machine on a VS 44HDxl unit via SETUP DIPS 1 2 3 and 4 according to Table 3 When using a standalone VS 44HDxl unit s...

Page 17: ...pter with a 9 wire flat cable to the RS 232 9 pin D sub port on your PC To connect a PC to the VS 44HDxl unit without using a Null modem adapter Connect the RS 232 9 pin D sub port on your PC to the R...

Page 18: ...twisted pair cable the shield is usually connected to the G Ground PIN of the first unit 2 Set the first VS 44HDxl unit as MACHINE 1 and the following seven VS 44HDxl units as MACHINE 2 to MACHINE 8...

Page 19: ...ling via ETHERNET You can connect the VS 44HDxl via the Ethernet using a crossover cable see section 6 8 1 for direct connection to the PC or a straight through cable see section 6 8 2 for connection...

Page 20: ...n Properties window appears 5 Select the Internet Protocol TCP IP and click the Properties Button see Figure 7 Figure 7 Local Area Connection Properties Window 6 Select Use the following IP address an...

Page 21: ...the REMOTE Connector You can force the routing of one of the four inputs to any of the four outputs1 by remote control To do so connect the appropriate REMOTE input terminal block connector pins to a...

Page 22: ...or standard definition or blue for high definition If an OUTPUT button is not selected that button will not illuminate If a source is connected to an INPUT that INPUT button will illuminate 7 1 1 Swit...

Page 23: ...tion is immediate and actions require no user confirmation However no protection is offered against changing an action in error In the CONFIRM mode You can key in several actions and then confirm them...

Page 24: ...TAKE button illuminates 7 3 Storing Recalling Input Output Configurations You can store and recall up to eight setup configurations using the four INPUT buttons and the four OUTPUT buttons The setup a...

Page 25: ...ct To cancel this action press the RCL button once again 7 4 Locking the Front Panel To prevent changing the settings accidentally or tampering with the unit via the front panel buttons lock1 your VS...

Page 26: ...ed GENLOCK 75 Hi Z on a BNC connector MAX OUTPUT LEVEL 800mVpp 75 ohms DATA RATE Up to 2 97Gbps CONTROLS Front panel RS 232 RS 485 ETHERNET infra red remote contact closure and panel lock POWER SOURCE...

Page 27: ...ON NO is the value to be set for N5 N0 2nd BYTE Bit 7 Defined as 1 I6 I0 INPUT When switching ie instruction codes 1 and 2 the INPUT 7 bits is set as the input number which is to be switched Similarly...

Page 28: ...outputs 3 number of setups 1 for video 14 NOTES on the above table NOTE 1 When the master switcher is reset e g when it is turned on the reset code is sent to the PC If this code is sent to the switch...

Page 29: ...equest for identification is sent with the INPUT set as 3 or 4 the appropriate machine will send its software version number Again the reply would be the decimal value of the INPUT and OUTPUT the INPU...

Page 30: ...tsofnature ii Product modification orfailureto followinstructions supplied with theproduct iii Repairorattemptedrepairby anyonenot authorizedbyKramer iv Anyshipment of theproduct claims must bepresent...

Page 31: ...or the latest information on our products and a list of Kramer distributors visit our Web site www kramerelectronics com where updates to this user manual may be found We welcome your questions commen...

Reviews: