![KRAL CKC Operating Instructions Manual Download Page 13](http://html1.mh-extra.com/html/kral/ckc/ckc_operating-instructions-manual_2000366013.webp)
6 Transportation, storage
6.5 Storing the pump
Fig. 6: Fastening of hoisting equipment - principle diagrams
1.
Attach the hoisting equipment to the pump/pump unit and tighten. Ensure that the centre of grav-
ity lies exactly under the crane hook.
2.
Lift the pump/pump unit carefully and put it down shock-free.
3.
Before loosening the transport belts ensure that the pump/pump unit is secured against tilting.
6.5 Storing the pump
During the test run, the internal components of the pump are wetted with test oil, which has a preser-
vative effect. Pressure connection and suction connection are closed with protective caps. Unless oth-
erwise specified, the outer surfaces of the pump are preserved with a single-coat PU-based two-com-
ponent paint.
The preservative applied at the factory will protect the pump for about six weeks, if it is stored in a dry
and clean location.
The manufacturer offers a long-term preservation for storage times of up to 60 months. The pump is
additionally packed in hermetically sealing anti-corrosion paper.
Personnel qualification:
o
Transport personnel
Aids:
o
Mobile crane, forklift, hoisting equipment
ATTENTION
Damage to equipment and corrosion if stored improperly and during longer standstills.
► Protect the pump against damage, heat, sunlight, dust and moisture.
► Protect against corrosion during longer standstill.
► Observe measures for storing and preservation.
1.
Store cool and dry and protect against sunlight.
2.
Ensure that the anti-corrosion paper is not damaged.
3.
Observe the intervals for preservation
Ä
Operating instructions
OIC 01en-GB Edition 2019-11
13