11 Menu description
11.4 Menu 2: General settings
Menu item
Description
1.09 Display direction
change Volumeter B
Shows the number of the flow direction changes of the flowmeter B since the last reset.
Requirement
:
2.13 Setting Function pulse inputs
Set to
Encoder
.
Note
:
The counter can be increased in case of a power failure even without change of direction. Recom-
mendation: Reset the counter before starting the measurement.
1.10 Display reset
bypass and group error
message
Reset the group error message after eliminating the cause for the activation of the collective error
message and bypass valve.
1.11 Setting Display
brightness
Adjust the brightness of the display
1.12 Setting Display
contrast
Adjust the contrast of the display
1.13 Setting Select
language
Selection of the language
1.30 Setting Enter
password
Allows password entry, can only be reached via
2.01 Setting Enable password
or
2.02 Setting
Change password
.
1.31 Help on operation
Shows the brief instruction.
11.4 Menu 2: General settings
o
Changing general settings in accordance with the requirements of the measuring task
o
Changes only possible with password
o Ä
Menu item
Description
2.01 Setting Enable
Password
Factory settings:
o
Password:
1000
o
Password protection:
Yes
Yes
o
Password protection is active - no changes is possible
No
o
Password protection is not active - changes are possible
2.02 Setting Change
password
Change the password
2.03 Setting Select
mode
Selection of the mode is adjusted to the measuring task.
Volume
Volumetric flow rate measurement without consideration of temperature influences.
Volume at X°
Q
,
QA
or
QB
are converted with temperature and density table to mass. Then a conversion takes
place with the
Volume at X°
density table.
Volume at TempA
Calculates the consumption at the temperature flowmeter A. This temperature usually corresponds to
the temperature of the liquid in the reservoir.
When a mass unit is selected, the system changes automatically to the mass calculation mode.
Note
:
Reference temperature
X°
Is freely selectable, see
2.04 Setting select temperature X
2.04 Setting select tem-
perature X
Setting the reference temperature
Requirement:
2.03 Setting Select mode
set to
Volumes for X
.
2.05 Setting Select unit
rate
Set values unit rate
2.06 Setting Select unit
total
Set values unit total
Operating instructions
OIE 12en-GB Edition 2020-03