![KRAL BEM 300 Series Operating Instructions Manual Download Page 30](http://html1.mh-extra.com/html/kral/bem-300-series/bem-300-series_operating-instructions-manual_2000350030.webp)
30
OIE 15en Edition 2019-12 HW 2.0/SW 2.0
Operating Instructions
Menu 2: Settings
Menu description
In order to avoid this a different unit can be selec-
ted or the number of decimal places reduced, see
"Further faults", page 35.
Resetting the total values:
1. Press SET.
ΣA1 is selected.
2. Press SET for three seconds.
The total value T1 is reset.
3. Press SET.
ΣA2 is selected.
4. Press SET for three seconds.
The page for entering the password is dis-
played.
5. Enter the password.
The total value ΣA2 is reset.
1.03 Reset collective error message
After the cause for the activation of the collective
error message has been eliminated, this function
is used for resetting.
1.04 Information
1.05 Setting display brightness
The brightness of the display is adjusted on this
page.
1.06 Setting display contrast
The contrast of the display is adjusted on this
page.
Pages 1.07 and 1.12 are described separately,
see "Shortcut pages", page 29.
1.07 Setting select language
The language is selected on this page. The page
can be called up via shortcut, see "1.07 Langu-
age selection", page 29.
Menu 2: Settings
Menu 2 allows adaptation in accordance with the
requirements of the measuring task. All the set-
tings can only be changed after the password
has been entered.
2.01 Enable password
Factory settings:
□
Password: "1000"
□
Password protection active (setting "Yes")
Deactivate password protection:
Number of
decimal pla-
ces
Minimum value Maximum
value
3
-1 999 999,999 1 999 999,999
1
-199 999 999,9 199 999 999,9
Setting
Meaning
Yes
□
Password protection is active
□
No changes possible
No
□
Password protection is not
active
□
Changes are possible
1.07 Setting
Select
Language
English
2.01 Setting
Enable
Password:
Yes
Summary of Contents for BEM 300 Series
Page 1: ...Operating Instructions KRAL Electronics BEM 300 Series OIE 15en Edition 2019 12 HW 2 0 SW 2 0 ...
Page 45: ...Operating Instructions OIE 15en Edition 2019 12 HW 2 0 SW 2 0 45 Notes Appendix Notes ...
Page 46: ...46 OIE 15en Edition 2019 12 HW 2 0 SW 2 0 Operating Instructions Notes Appendix Notes ...
Page 47: ...Operating Instructions OIE 15en Edition 2019 12 HW 2 0 SW 2 0 47 Notes Appendix Notes ...
Page 48: ...www kral at KRAL GmbH 6890 Lustenau Austria Tel 43 5577 86644 0 E Mail kral kral at ...