KRAFTWERK 38125 Instruction Manual Download Page 4

4

MAINTENANCE

1. When the body repair kit is not in use, the pump unit should be 
    stored with the release valve open.
2. To check oil level, place the pump unit in an upright position. As 
    indicated on the diagram opposite. Remove the dip stick and the 
    oil level will be indicated. If required add hydraulic oil until it is 
    level with the full mark on the stem. 
3. After extensive use, the oil supply should be replaced to ensure 
    longer equipment life. To drain, remove the dip stick and open 
    release valve. Ensure that no dirt gets into the system. Refill with 
    approved jack oil.

IMPORTANT:
USE ONLY CERTIFIED HYDRAULIC OIL WHEN TOPPING UP AND 
REPLACING THE OIL.

www.KRAFTWERKtools.com

EN 1494: 2000+A1/2008

DECLARATION OF CONFORMITY 

Model: 

38125

Portable hydraulic body repair kit 10 t

KRAFTWERK Sàrl, 

25 rue due Stade, F-67870 Bischoffsheim

Declares under sole responsibility that the product to which this declaration relates is in conformity with the following 
standard(s) or other normative document(s):

Following the provisions of Directive(s)
Machinery Directive:

Bischoffsheim, 28/02/2013  

 

 

2006/42/EC 

         Patrick Wyss 

         President 