Digital multimeter

ENGLISH

ENG

ENG

KPS SOLUCIONES EN ENERGÍA, S.L.

Parque Empresarial de Argame,

C/Picu Castiellu, Parcelas i-1 a i-3

E-33163 Argame, Morcín

Asturias, España, (Spain)

See the full

instruction manual:

Description

•  The  multimeter  is  a  portable,  hand-held  yet  professional    meter  that  features  True 

RMS  measurement  display,  AC/DC  current,  AC/DC  voltage,  Frequency,  Capacitance, 

Resistance,  Continuity,  Duty  Ratio,  Diode  Testing  and  a  USB  adapter  for  recording 

readings on a PC. This Meter is easy to use even with one hand, suitable for professional 

users or amateurs, and ideal for school or home use. 

•  Both auto and manual range.

•  Display hold

•  True RMS for AC voltage/current measurements

•  Relative measurement

•  Maximum measurement

•  Minimum measurement

•  Display frequency when measuring AC voltage/current 

•  Automatic Power Off

Safety Information

WARNING

Use caution and follow all safety guidelines to prevent electric shock or damage to the meter.

Please ready carefully all instructions before use. If the equipment is used in a manner not  

specified by the manufacturer, the protection provided by the equipment may be impaired.

The  multimeter  meets  the  safety  standards  of  EN/UL/CSA  61010-1,  61010-2-030,  

61010-2-033  for  electronic  testing  instruments.  This  meter  meets  CAT  III  1000V,  

CAT IV 600V installations and a pollution degree of 2.

Preparation

•  When using the meter, follow all standard safety guidelines: 

 - For universal protection again electric shock.

 - To prevent the misuse of the instrument. 

•  Check the meter for damage during transit.

•  Test leads must be in good condition.Check the insulation and tips before use.

•  Safety can only be guaranteed with leads provided. 

•  lf  leads  need  to  be  replaced,  they  must  be  replaced  with  leads  of  same  electrical 

specifications.

Using the Meter

•  Always set the meter to the proper function and range first. 

•  Never exceed protection limits indicated for each measurement. 

•  Keep fingers behind the probe barriers while measuring. 

•  Always be careful when working with voltages above 60V DC or 30V AC RMS. 

•  When  using  the  CAT  IV  environment,if  the  measuring  voltage  between  terminals  and 

earth ground exceeds 600V CAT III environments or voltage measurement between the 

terminal and the earth more than 1000V, do not measure voltage. 

•  In manual range, if the circuit value is unknown, start the meter at the maximum range and 

then adjust accordingly. 

•  Remove the leads from the circuit first before switching between functions. 

•  Do not power on circuit while measuring resistan ce, capacitance, diodes and continuity. 

•  Never connect the meter’s leads across a voltage source while the rotary switch is in the 

resistance,capacitance, diode or continuity mode. 

•  Do not measure capacitance befare capacitors are discharged. 

•  Do not operate the meter near explosive gas, vapor or dust. 

•  Stop using the meter if any abnormality is observed.

•  Do not use the meter unless the battery cover is securely fastened to the meter.

•  Avoid direct exposure to sunlight to ensure extended life of the meter.

Maintenance

•  To avoid electric shock or personal injury, repairs/servicing not covered in this manual 

should be performed only by qualified personnel. 

•  Remove test leads from any circuit before opening battery cover. 

•  To  avoid  false  readings  that  may  become  dangerous,  replace  the  battery  as  soon  as  

the  

 symbol appears. 

•  Clean the meter using a damp cloth and mild detergent only; do not use abrasives or 

chemical solvents. 

•  Always move rotary switch to OFF when not using the meter.

•  lf meter is not going to be used for an extended period of time, remove battery to prevent 

damage to the meter.

Replacing the Battery and Fuse

WARNING

To avoid electrical shock or personal injury, before opening the battery cover to replace 

battery, you should turn the meter off and make sure that the test probe is disconnected 

from the measurement circuit. 

To avoid wrong readings, electric shock or personal injury, when “

” appears on the meter 

display, replace the battery immediately.

Use only a fuse with specified amperage, fusing rated

value, voltage rated value and fusing speed

( F1: FF 600mA H 1000V, F2: FF 10A H 1000V)

    

Please follow below steps to replace battery or fuse:

•  Turn off the power supply of the meter.

•  Pull out all test probes from the input socket.

•  Loosen two screws on the fixed battery cover with screwdriver.

•  Remove the battery cover.

•  Remove the old battery or damaged fuse.

•  Replace with a new battery with 9V (NEDA 1604, 6F22 or 006P) or a new fuse.

•  Replace the battery cover and tighten the screws.

Note:

Pay attention to the polarity of the battery to avoid damage to the meter.

Replacing Test Probe

If insulation on leads is damaged, replace it.

WARNING

If the test leads need to be replaced, you must use a new one which should meet EN 

61010-031 standard, rated CAT III 1000V/CAT IV 600V, 10A or better.

Accessories

Test leads   

 

 

1 pair

Summary instruction manual 

 

1 pc

Battery 9V 6F22 

 

 

1 pc

USB interface cable   

 

1 pc

USB interface software  CD ROM disc 

1 pc

APAC: 

MGL GLOBAL SOLUTIONS LTD

[email protected]

Flat 4-1, 4/F, No. 35, Section 3 Minquan 

East Road. Taipei, Taiwan.

Tel: +886 2-2508-0877

EMEA: 

MGL EUMAN S.L.

[email protected]

Parque Empresarial Argame, 33163 

Morcín. Asturias, Spain.

Tel: +34 985-08-18-70

AMERICAS: 

MGL AMERICA, LLC.

[email protected]  

US East Coast:

 2810 Coliseum Centre 

Drive, Ste. 100. Charlotte, North Carolina, 

28217 USA

Tel: +1 833 533-5899

US West Coast:

 760 Challenger Street. 

Brea, California 92821 USA

Tel: +1 310-728-6220

www.mgl-intl.com

Reviews: