Dimensions (W x H x D)
:
Approx. 130mm x 350mm x 25mm
Weight(without Battery) :
200g
Power Requirements :
AAA Size Battery x 2
Battery Life :
160 hours ALKALINE Battery
Low Batteries Indication :
Voltage drops below operating voltage the
battery indicator will flash.
Maximum Conductor Size :
coil size
Safety Standard :
EN61010-1, EN61010-2-032, EN61010-031
EN61326-1
CAT IV 600V, CAT III 1000V
General Specifications
Indoor Use.
Pollution Degree
:
2
Maximum operating altitude :
2000m (6562 ft)
Operating temperature & Relative Humidity :
0°C - 30°C,
≦
80%RH
30°C - 40°C,
≦
75%RH
40°C - 50°C,
≦
45%RH
Storage temperature :
-20°C - 60°C, 0 to 80% RH (no batteries).
Temperature coefficient :
0.2 x (Specified accuracy) / °C, < 18°C, > 28°C
Shock vibration :
Sinusoidal vibration
MIL-PRF-28800F (5-55 Hz, 3g max.)
Drop Protection :
4 feet drop to hardwood on
concrete Floor
Environmental Specifications
Accuracy is given as ±(% of r counts
of least significant digit) at 23°C ± 5°C, with
relative humidity Less than 80% R.H.
Accuracy is specified for a period of one year
after calibration.
Max. output voltage:
4.5Vpeak
Position Error of Clamp:
Accuracy and position error assumes centralized
primary conductor at optimum position, no external electrical or
magnetic field, and within operating temperature range.
Electrical Specifications
EN
DCM3018FLEX
Distance from
Optimum (mm)
sFlex-18T
Error
35
±1.0%
50
±1.5%
60
±2.0%
5