![KPS 602350006 Instruction Manual Download Page 23](http://html.mh-extra.com/html/kps/602350006/602350006_instruction-manual_1999954023.webp)
23
KPS-MT20L • Non-contact voltage detector
ENG
3.2.2 AC Voltage
Range
Resolution
Accuracy
200mV
0,1mV
±( 0,8% of r 3 digits )
2V
0,001V
20V
0,01V
200V
0,1V
600V
1V
±( 1,0% of r 3 digits )
- Input Impedance: 10MΩ
- Overload Protection: 200mV range: 250V DC or AC rms, 2V-600V ranges:
DC 600V or AC 600V rms.
- Frequency Range: 40 to 400Hz
- Response: Average, calibrated in rms of sine wave.
- Max. Input Voltage: 600V rms AC
3.2.3 Resistance
Range
Resolution
Accuracy
200Ω
0,1Ω
± ( 1,0% of r 3 digits )
2kΩ
0,001kΩ
± ( 1,0% of r 1 digit )
20kΩ
0,01kΩ
200kΩ
0,1kΩ
2MΩ
0,001MΩ
20MΩ
0,01MΩ
± ( 1,0% of r 5 digits )
- Open Circuit Voltage: 0.25V
- Overload Protection: 250V DC or rms AC