1 2
c.shut off the main burner:
the main burner is on
“
OFF
”
selection,.
The main burner will shut off.
n
OPERATIONS OF
n
TIMING
1
.Auto on:
when the burner is in a state of
readiness. Transmitter and burner is
off. Press TIMER button. Then press
▲
or
▼
change to the scheduled time,
then press the TIMER button again, the
TIMER starts timing and the TIMER is
flashing and the operation light(green)
begin flashing. When the timer goes
on the scheduled time, the burner
opens automatically.
2
.Auto off:
when the burner is in operation, press
TIMER button. Then press
▲
or
▼
to
change to the scheduled time, then
press the TIMER button again, the
TIMER starts timing and the TIMER is
flashing and the operation light begin
flashing. When the timer goes on the
scheduled time, the burner closes
automatically.(See Fig 14)
n
OPERATIONS OF
n
TURN-OFF
1.Manual turn-off: when the heater is in
operation, press the IGN/OFF button to
shut off the heater.
2.Auto turn-off: refer to the second step
of
“
Operations of Timing
”
n
OPERATIONS OF
n
BURNER
1.Plug-in 110V electrical outlet, you
will hear a high pitch sound and
power light(red) on the front will be lit
that indicates that the burner is ready
to be operated. Before plugging in the
outlet make sure that the appliance is
connected to the gas supply, then
continue to the next step.
2.Point directly the remote transmitter
to the burner. Press IGN/OFF button,
the electric spark starts igniting the
pilot and operation light (green) on the
front will be lit. Wait five (5) minutes to
clear out any air. If you smell gas.
S T O P ! P le a s e c h e c k t h e g a s
connection.
There are three selections:
“
AUTO
”
“
MAN
”
and
“
OFF
”
a.
auto select of main burner:
Fig16 Control board
Fig 14 Back of the Transmitter
n
OPERATIONS OF
n
REMOTE TRANSMITTER
1.Install three AAA SIZE batteries in the
battery holder.
The initial start-up on the LCD is: SET
TEMP is 77
°
F, ROOM TEMP is 77
°
F,
clock is AM12:00, burner is on
“
OFF
”
select, and fan is on
“
AUTO
”
select. Di-
vide Points of hour and minute are flash-
ing (i.e. the timer is operating).
2.Clock setting: Press CLOCK button
on the remote transmitter panel to se-
lect item (hour, minute). The selected
item is flas h in g . P ress
▲
o r
▼
to
change to the correct actual hour(s);
Press
▲
or
▼
to change to the correct
minute(s), then press CLOCK button
again, time setting is finished.
3. When in operation, point the remote
transmitter to the remote receiver on the
burner in a maximum distance of 20
feet without any obstruction between
them.
Fig 15 Initial start-up on the LCD
OPERATING
HEATER
Continued
NOTE:
The thermostat sensing bulb
measures the temperature of air near
the heater cabinet.This may not always
a g r e e w it h r o o m t e m p e r a t u r e
(depending on housing construction,
installation location, room size, open
air temperatures,etc.)Frequent use of
your heater will let you determine your
own comfort levels.
b.
manual select of main
burner:
(Note: on the auto select of main
burner, the main burner does not re-
spond imm-ediately to the set tem-
perature until about one minute later.)
Press BURNER button, the flame
is on
“
AUTO
”
select. Press
▲
or
▼
to
set temperature. If the room tempera-
ture is two degree lower than the set
temperature on the remote, the main
burner will turn on until the surrouding
temperature is two degree higher than
the set temperature. Once it reaches
temperature on the remoter, the main
burner will automatically shut off.
Press BURNER button, the flame
is on
“
MAN
”
select. At this selection,
the main burner will keep working no
matter what the temperature is set at.
If there is a need to shut off the main
burner, just press the
“
BURNER
”
but-
ton to make the burner on the
“
OFF
”
select.