Kozy-World FBD3211R Manual Download Page 29

 

29 

REPLACEMENT PARTS 

 

NOTE: 

Use only original replacement parts. This will protect your warranty coverage for parts replaced under 

warranty. 

 
PARTS UNDER WARRANTY  

Contact authorized dealers of this product. If they can

t supply original replacement parts, call Customer Service toll 

free at 

(814)643-1775

 for referral information.  

 
When calling Customer Service or your dealer, have ready: 

·

 

Your name 

·

 

Your address 

·

 

Model and serial number of your heater 

·

 

How heater was malfunctioning 

·

 

Type of gas used (Propane/LP or Natural gas/NG) 

·

 

Purchase date 

·

 

Usually, we will ask you to return the defective part to the factory 

 

PARTS NOT UNDER WARRANTY  

Contact authorized dealers of this product. If they can

t supply original replacement part(s) call Customer Service toll 

free at 

(814)643-1775

 for referral information. 

 
When calling Customer Service have ready: 

·

 

Model number of your heater 

·

 

The replacement part number 

 

World-Marketing of American, Inc. 
P.O. Box 192, Rt. 22 West 
MillCreek, PA 17060 
 
KOZY-WORLD PHONE NUMBER :( 814)643-1775 
 
http://www.worldmkting.com

 

Summary of Contents for FBD3211R

Page 1: ...OR LOSS OF LIFE WM FBD3211R 0903 CAUTION FOR YOUR SAFETY This is an unvented gas fired heater It uses air oxygen from the room in which it is installed Provisions for adequate combustion and ventilat...

Page 2: ...tallation Failure to follow these instructions may result in a possible fire hazard and will void the warranty PRODUCT SPECIFICATIONS MODEL FBD3211R Input Rating 32 000 BTU Hr 32 000 BTU Hr Gas Type N...

Page 3: ...AS Natural and Propane LP gases are odorless An odor making agent is added to the gas The odor helps you detect a gas leak However the odor added to the gas can fade Gas may be present even though no...

Page 4: ...before servicing Only a qualified service person should service and repair heater 10 Operating heater above elevations of 4 500 feet could cause pilot outage 11 To prevent performance problems do not...

Page 5: ...husetts Sellers of unvented propane or natural gas fired supplemental room heaters shall provide to each purchaser a copy of 527 CMR 30 upon sale of the unit In the State of Massachusetts unvented pro...

Page 6: ...ne 1 ounce 30 mL of water for every 1 000 BTUs 3 kw of gas input per hour An unvented room heater is recommended as a supplemental heater a room rather than a primary heat source an entire house In mo...

Page 7: ...less provisions are provided for adequate combustion and ventilation air Adjoining rooms are connecting only if there are doorless passageways or ventilation grills between them Unusually Tight Constr...

Page 8: ...fresh air Your options are as follows a Rework worksheet adding the space of an adjoining room If the extra space provides an unconfined space remove door to adjoining room or add ventilation grills...

Page 9: ...provide two permanent openings one within 12 inches of the ceiling and one within 12 inches of the floor Connect these items directly to the outdoors or spaces open to the outdoors These spaces includ...

Page 10: ...air exist may cause walls to discolor WARNING Maintain the minimum clearances If you can provide greater clearances from floor ceiling and adjoining side and back walls IMPORTANT Vent free heaters ad...

Page 11: ...peration Walls and mantels above the firebox may become hot to the touch If installed properly these temperatures meet the requirement of the national product standard Follow all minimum clearances sh...

Page 12: ...ebox front facing WARNING Do not allow combustible or noncombustible materials to cover any necessary openings like louvered slots WARNING Never modify or cover the louvered slots on the front of the...

Page 13: ...d equipment shutoff valve with 1 8 in NPT tap is an acceptable alternative to test gauge connection Purchase the optional CSA design certified equipment shutoff valve from your dealer WARNING Never co...

Page 14: ...going into pipe Excess sealant in pipe could result in clogged heater valves CAUTION Use pipe joint sealant that is resistant to gas PROPANE or NG We recommend that you install a sediment trap in a s...

Page 15: ...ction valve must be locked into the NG position Do not operate heater between locked positions 3 Rotate and close cover over gas selection valve and reinstall screw 4 Remove steel or metal hex plug wi...

Page 16: ...s forming show a leak 5 Correct all leaks immediately 6 Reconnect heater and equipment shutoff valve to gas supply Check reconnected fittings for leaks Test Pressures Equal To or Less Than 1 2 PSIG 3...

Page 17: ...er The remote receiver operates on four 1 5V AA size batteries It is recommended that ALKALINE batteries be used for longer battery life and maximum microprocessor performance IMPORTANT New or fully c...

Page 18: ...ogs according to the log installation instructions in this manual Flames contacting logs will create soot Figure 22 Installing Log Set IMPORTANT Make sure log does not cover any burner ports see Figur...

Page 19: ...ection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions...

Page 20: ...s heavier than air and will settle on the floor WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Immediately call...

Page 21: ...ob should be depressed for about thirty 30 seconds This will allow gas to bleed from the gas system 5 With the control knob pressed in push down and released the ignitor button This will light the pil...

Page 22: ...de SET Sets temperature in thermo mode LCD Liquid Crystal Display 1 DISPLAY Indicates CURRENT room temperature 2 F OR C Indicates degrees Fahrenheit or Ceisius 3 FLAME Indicates bumer valve in operati...

Page 23: ...SET key The LCD screen will display the set temperature for 3 seconds Then will flash the set temperature for 3 seconds Then the LCD screen will default to display the room temperature Press the MODE...

Page 24: ...BURNER FLAME PATTERN Figure 36 shows a correct burner flame pattern Figure 37 shows an incorrect burner flame pattern If pilot flame pattern is incorrect then If burner flame is incorrect turn heater...

Page 25: ...no greater than 30 PSI You can use a vacuum cleaner in the blow position If using compressed air in a can please follow the directions on the can If you don t follow directions on the can you could da...

Page 26: ...wrong 2 Ignitor electrode is broken 3 Ignitor electrode is not connected to ignitor cable 4 Ignitor cable is pinched or wet 5 Damaged ignitor cable 6 Bad piezo ignitor 7 Low battery 1 Replace electrod...

Page 27: ...stomer service 3 Contact your gas supplier Delayed ignition of burner s 1 Manifold pressure is too low 2 Burner orifice is clogged 1 Contact your gas supplier 2 Clean burner see Care and Maintenance P...

Page 28: ...urniture 1 When heated the vapors from furniture polish wax carpet cleaners etc turn into white powder residue 1 Turn heater off when using furniture polish wax and carpet cleaner or similar products...

Page 29: ...serial number of your heater How heater was malfunctioning Type of gas used Propane LP or Natural gas NG Purchase date Usually we will ask you to return the defective part to the factory PARTS NOT UN...

Page 30: ...2D201 Hood 1 6 FB32D303 ODS Inlet Tube 1 7 FB32D302 Outlet Tube 1 8 FB32D301 Inlet Tube 1 9 RV83FI 4 9 DF Regulator 1 10 AF 1110 Valve 1 11 FB32D500 Logs Assembly 1 12 FB32D501B Log 1 1 13 FB32D502B L...

Page 31: ...31 Printed in China...