SAFETY INFORMATION                           

 

Installation  and  repair  should  be  done  only  by  a  qualified  service  person.  The  appliance  should  be  inspected  by  a  
qualified service person before use. Annual inspection by a qualified service person is required to maintain warranty. 
More frequent cleaning may be required due to excessive lint from carpeting, bedding materials, etc. It is imperative 
that  control  compartments,  burners  and  circulation  air  passageways  of  the  appliance  be  kept  clean.  

If  this  appliance  is  installed  directly  on  carpeting,  tile  or  other  combustible  material  other  than  wood  flooring,  the  
appliance  shall  be  installed  on  a  metal  or  wood  panel  extending  the  full  width  and  depth  of  the  appliance.  

Children and adults should be alerted to the hazards of high surface temperatures and should stay away to avoid burns 
or clothing ignition.  

Young  children  should  be  carefully  supervised  when  they  are  in  the  same  room  as  the  appliance.  Toddlers,  young  
children and others may be susceptible to accidental contact burns. A physical barrier is recommended if there are at 
risk individuals in the house. To restrict access to a fireplace or stove, install an adjustable safety gate to keep toddlers, 
young children and other at risk individuals out of the room and away from hot surfaces.   

Clothing or other flammable material should not be placed on or near the appliance. 

Adequate accessibility clearances for servicing and proper operation must be maintained.   

This appliance must not share or be connected to a chimney flue serving any other appliance.   

Keep area around the appliance clear of combustible materials, gasoline and other flammable vapor and liquids.  

The flow of combustion and ventilation air must not be obstructed. 

  

Due  to  high  temperatures  the  appliance  should  be  located  out  of  traffic  and  away  from  furniture  and  draperies. 

The  glass  front  or  any  part  removed  for  servicing  the  appliance  must  be  replaced  prior  to  operating  the  appliance. 
Work should be done by a qualified service technician.   

Clean glass only when cool and only with non-abrasive cleansers.   

WARNING: DO NOT OPERATE APPLIANCE WITH THE GLASS/FRAME ASSEMBLY REMOVED, CRACKED 
OR  BROKEN.  REPLACEMENT  OF  THE  GLASS  SHOULD  ONLY  BE  PERFORMED  BY  A  LICENSED  OR  
QUALIFIED SERVICE PERSON . 

The glass assembly, Part #SL42-057T,  shall only be replaced as a complete unit, as supplied by Hussong Mfg. Co., Inc. 
DO NOT SUBSTITUTE MATERIALS.   

Do not strike or slam glass assembly.   

Any  safety  screen  or  guard  removed  for  servicing  the  appliance  must  be  replaced  prior  to  operating  the  appliance. 

Under  no  circumstances  should  any  solid  fuel  (wood,  coal,  paper  or  cardboard  etc.)  be  used  in  this  appliance. 

Keep burner and control compartment clean. 

 

Do not use this fireplace if any part has been under water. Immediately call a qualified service technician to inspect this 
appliance  and  to  replace  any  part  of  the  control  system  and  any  gas  control  which  has  been  under  water. 

This fireplace has been tested by OMNI-Test Laboratories, Portland, Oregon and complies with:  
 
ANSI  Z21.88-2009/CSA 2.33-2009, “Standard for Vented Gas Fireplace Heaters.”   
CAN 2.14-M91 (R2009), “Gas-Fired for Use at High Altitudes.” 

  

CAN/CSA P.4.1-09, “Testing Method for Measuring Annual Efficiency”. 

 

 
This  installation  must  conform  with  local  codes,  or  in  the  absence  of  local  codes,  with  the 

National  Fuel  Gas  Code,  ANSI  Z223.1/NFPA  54,  

or the 

Natural Gas and Propane Installation Code, CSA B149.1    

   

Summary of Contents for Sla-42

Page 1: ...vice agency or the gas supplier WARNING If the information in these instructions is not followed exactly a fire or explosion may result causing property damage personal injury or loss of life This app...

Page 2: ...stomer safety as well We offer our continual support and guidance to help you achieve the maximum benefit and enjoyment from your Kozy Heat gas fireplace Jim Hussong Dudley Hussong President Board Cha...

Page 3: ...embly Removal Installation 13 GAS LINE CONNECTION Gas Line Connection 14 VENTING Approved Venting 15 Horizontal Vent System Clearances 15 Horizontal Termination Minimum Maximum 15 800 WPT Wall Pass Th...

Page 4: ...terials gasoline and other flammable vapor and liquids The flow of combustion and ventilation air must not be obstructed Due to high temperatures the appliance should be located out of traffic and awa...

Page 5: ...appliance or equipment The sign shall read in print no less the one half inch 1 2 in size GAS VENT DIRECTLY BELOW KEEP CLEAR OF ALL OBSTRUCTIONS INSPECTION The state or local gas inspector of the side...

Page 6: ...nd offs 0 Unit top to ceiling 31 787mm Side of finishing edge to adjacent sidewall 6 152mm Unit front to combustibles 36 914mm Mantel 9 129mm deep from fireplace finishing edge 10 3 4 273mm Figure 5a...

Page 7: ...he installation Mounting a TV above a fireplace has become common practice With this in mind we advise you to read the following paragraphs carefully before considering installing a television above y...

Page 8: ...with provided screws STAND OFF STAND OFF HEAT SHIELD ASSEMBLY INSTALLATION TOP STAND OFF BRACKETS AS SHIPPED REMOVE SCREWS SECURING STAND OFF BRACKETS ALIGN HOLES IN FORMED TOP STAND OFFS WITH HOLES I...

Page 9: ...ailing flange until parallel with fireplace face Do not bend toward fireplace face 4 Position framing stud against 1 2 13mm long stand off located on backside of nailing flange Secure with nails or sc...

Page 10: ...ation below provided it is properly supported by framing materials and ceiling clearances are maintained If installing optional 970 Heat Duct Kit refer to installation instructions on pages 29 32 of t...

Page 11: ...and height If a hearth extension is desired combustible material may be used Figure 10a CAUTION Cold air transfer area The surrounding fireplace chase must comply with all clearances as outlined in t...

Page 12: ...ith screws which may damage control system components Use a silicone sealant that has a 300 F 149 C continuous exposure rating to secure material in this zone It is acceptable to pre drill holes and u...

Page 13: ...instructions on page 16 of this installation manual The horizontal heat shield included with this fireplace must be installed when incorporating minimum horizontal venting This applies to Nat and LP m...

Page 14: ...ts securing component upper heat shield Pull component board forward secured to hear shield with magnet Remove heat shield 4 Locate 2 spring loaded handles at bottom of firebox Pull handles out and do...

Page 15: ...des if any If not follow ANSI 223 1 Commonwealth of Massachusetts Installation must be done by a licensed plumber of gas fitter NOTE A listed and Commonwealth of Massachusetts approved 1 2 13mm T hand...

Page 16: ...NG This fireplace is designed to be used with any of the following vent systems without the use of an additional adaptor Refer to vent manufacturer s installation manual for complete installation inst...

Page 17: ...ATION HEAT SHIELD MUST BE FLUSH WITH WALL PASS THRU 3 8 10mm FLANGE MUST BE ON INSIDE WALL Figure 16a IMPORTANT 800 WPT or 800 WPT2 Wall Pass Thru must be used on all horizontal vent terminations This...

Page 18: ...m vertical rise 9 229mm horizontal MAXIMUM 18 457mm vertical rise Max 12ft 3 66m horizontal For horizontal runs greater than 2ft 601mm 18 457mm minimum vertical rise is required HORIZONTAL RUN VERTICA...

Page 19: ...mmendations depending on burner flame appearance and instructions on installation after venting is completed RESTRICTOR VERTICAL VENT SYSTEM CLEARANCES TOP BOTTOM SIDES ALL APPROVED VERTICAL PIPE 1 in...

Page 20: ...m wall thickness must be used on all horizontal vent runs Horizontal sections require 1 4 6mm rise for every 12 305mm of travel HORIZONTAL VERTICAL COMBINATION VENTING ELBOWS VENTING Figure 19b Figure...

Page 21: ...ace D Secure with 3 evenly spaced screws ILLUSTRATION ON FOLLOWING PAGE 4 Place a bead of sealant outside 5 flex pipe collar C end with EXTERNAL lip sliding it inside 5 pipe on top of fireplace D Secu...

Page 22: ...EXTENSION KIT E 8 FLEX PIPE COLLAR F 8 PIPE ON FIREPLACE OR EXTENSION KIT G VINYL SIDING PROTECTOR not shown H INTERIOR FIRESTOP FLEXIBLE 800 1 SERIES cont Bend tabs up before attaching 8 flex pipe co...

Page 23: ...of 15ft 4 57m US I Gas Service regulator vent outlet CANADA 3ft 914mm US J Non mechanical air supply inlet to building or the combustion air inlet to any other appliance CANADA 12 305mm US 9 229mm K...

Page 24: ...2 to 20 12 7 5 2 27 Over 20 12 to 21 12 8 0 2 44 VENT TERMINATION CLEARANCES VENTING Vertical Cap Requirements CAUTION This appliance must not be connected to or joined with any chimney flue serving a...

Page 25: ...nents Follow instructions included with conversion kit sold separately CAUTION Disconnect all electric power from fireplace before performing this task NOTE To avoid damage and prolong the life of hal...

Page 26: ...t bar onto control board secure with 2 nuts previously removed 3 Reinstall burner positioning burner venturi over burner orifice aligning burner tube with mounting cradles on control board 4 Reinstall...

Page 27: ...s frame assembly glass media burner cover and burner from fireplace 2 Loosen burner venturi screw make adjustment retighten screw 3 Re install burner making sure venturi is positioned over burner orif...

Page 28: ...inutes If flames indicate there is excessive draft flickering short flames a restrictor may be necessary If flames indicate insufficient draft lifting or ghosting flames a previously installed restric...

Page 29: ...ansers WARNING DO NOT OPERATE APPLIANCE WITH GLASS FRAME ASSEMBLY REMOVED CRACKED OR BROKEN REPLACEMENT OF THE GLASS SHOULD ONLY BE PERFORMED BY A LICENSED OR QUALIFIED SERVICE PERSON Use protective g...

Page 30: ...flexible heat duct pipe expandable to 20ft 6 10m 2 Mounting bracket screws 1 Register mounting frame with collar 11 Sheet metal screws 1 Register cover with screws 4 Sheet rock screws 1 Duct collar 3...

Page 31: ...ctly below previously removed knock out 4 Slide duct collar with circulation holes facing downward into 6 knock out until it rests on top of heat shield 1 Slide 6 152mm duct pipe s over collar s until...

Page 32: ...on 4 Attach but do not tighten flange nuts to mounting studs at back of register mounting bracket 5 Align 3 slots on fan assembly to studs slide fan into position Tighten nuts to secure 6 Slide fan wi...

Page 33: ...with 4 screws provided 3 Slide speed control through mounting bracket secure with mounting nut 4 Secure mounting bracket to junction box with 2 screws provided 5 Install register cover by centering it...

Page 34: ...in material or workmanship at Hussong Manufacturing Co Inc s expense including reasonable labor costs to repair or replace the defective component if a factory pre authorization is given for the repa...

Page 35: ...RISQUE DE BR LURES NE PAS TOUCHER UNE VITRE NON REFROIDIE NE JAMAIS LAISSER UN ENFANT TOUCHER LA VITRE AVERTISSEMENT Test et homologu par Nous recommandons de confier l installation et l entretien de...

Page 36: ...onnel 4 SCH MA DE C BLAGE Sch ma de c blage 5 INSTRUCTIONS D UTILISATION Composants du syst me de contr le 6 Utilisation du syst me 7 10 Instructions pour allumer et teindre le foyer 11 12 Tests de pr...

Page 37: ...ommand e s il y a des personnes risque dans la maison Pour restreindre l acc s un foyer ou po le installez une barri re de s curit ajustable pour loigner les bambins les jeunes enfants et autres perso...

Page 38: ...6 16 kW ATTENTION INSTALLATIONS HAUTE ALTITUDE Aux tats Unis Cet appareil peut tre install plus hautes altitudes Veuillez vous r f rer aux directives de l AGS American Gas Association qui sp cifient...

Page 39: ...cteurs aux bornes des moteurs de ventilateurs 3 Le moteur du ventilateur droit vers le bas et du c t droit ins rez le l entr e de la chambre de combustion Figure 3 4 D gagez le moteur de la fa ade du...

Page 40: ...VENTILATEUR ET LE SYST ME D CLAIRAGE NE FONCTIONNERONT PAS SUR LE BLOC PILES DE SECOURS Figure 5a Br leur Proflame 885 Bloc piles de secours Interrupteur principal ON OFF Ventilateur vitesse variable...

Page 41: ...ON SMART Point de consigne Temp rature Niveau tat Flamme ON Ventilateur Verrouillage de s curit enfants Alarme de faible charge des piles Temp rature ambiante ROBINET DE CONTR LE DE GAZ Connexion de...

Page 42: ...ontinuer Figure 7a Bouton SW1 Voyants DEL 5 Appuyez sur le bouton d interrupteur rouge SW1 du module de contr le IFC jusqu ce que le module mette trois 3 bips et ou qu un voyant orange DEL diode lectr...

Page 43: ...l commande THERMOSTAT INTELLIGENT SMART Utilisation la t l commande R GLAGE DE VITESSE DU VENTILATEUR KIT D CLAIRAGE ACCENT non disponible sur certains mod les de foyer 1 Appuyez sur la touche MODE p...

Page 44: ...I Voyants DEL BLOC PILES DE SECOURS utilis lors d une coupure de courant La dur e de vie des piles du bloc piles de secours d pend de divers facteurs qualit des piles fr quence des demandes d allumage...

Page 45: ...des avant que le br leur principal s allume Si apr s ce troisi me essai il n y a toujours pas d allumage le module de contr le IFC tombera en mode VERROUILL et le voyant DEL rouge clignotera 3 fois pa...

Page 46: ...qualifi pour faire inspecter ce foyer et pour remplacer toute pi ce du syst me de contr le qui aurait t en contact avec l eau ATTENTION LES ENFANTS ET LES ADULTES DOIVENT TRE SENSIBILIS S AUX RISQUES...

Page 47: ...pas joindre votre fournisseur de gaz appelez le service d incendie 4 Rebranchez le cordon d alimentation lectrique du foyer puis r tablissez toute alimentation lectrique au foyer 5 Appuyez sur le bou...

Page 48: ...raccord de test de pression de sortie Manifold Vis du raccord de test de pression d entr e 1 Desserrez la vis du raccord de test de pression d entr e IN en sens antihoraire sens inverse des aiguilles...

Page 49: ...surez vous que toutes les connexions entre les faisceaux de c bles et les composants du syst me sont correctes et fonctionnelles Assurez vous que le lien de communication entre la t l commande manuell...

Page 50: ...verre pastilles de verre Voir les instructions correspondantes dans le manuel d installation de ce foyer R glage incorrect du venturi Vous devrez peut tre ouvrir l g rement le venturi pour laisser pa...

Page 51: ...ez votre fournisseur de gaz local ou les autorit s ayant juridiction pour les m thodes de recalibrage appropri es angl de rating methods ATTENTION MISE EN GARDE AVANT DE COMMENCER LA CONVERSION L ALIM...

Page 52: ...nt rieur du venturi du br leur et que le tube appuie dans les supports de fixation 3 R installez le plateau du br leur en alignant les trous de fixation avec les trous correspondants sur les supports...

Page 53: ...ont bleues Les flammes passeront graduellement la couleur jaune orange durant les 15 premi res minutes de fonctionnement Si les flammes restent bleues ou deviennent orange fonc avec des signes de suie...

Page 54: ...LISEZ PAS CET APPAREIL SI LA VITRE EST RETIR E FISSUR E OU CASS E LE REMPLACEMENT DE LA VITRE DOIT TRE EFFECTU SEULEMENT PAR UN PROFESSIONNEL D ENTRETIEN CERTIFI OU QUALIFI Utilisez des gants protecte...

Page 55: ...Robinet IPI S I T Gaz naturel 700 203 Robinet d arr t manuel 700 567 1 Robinet IPI S I T Gaz propane GPL 700 213B Conduite de gaz flexible 18 po Noir 700 652 Module de contr le IFC Proflame 2 700 226...

Page 56: ...he time of this Lifetime Warranty or to accept on Hussong Manufacturing Co Inc s behalf any additional obligation of liability connected with the unit Hussong Manufacturing Co Inc may fully discharge...

Reviews: