kozy heat NCK-SL42-SPB Manual Download Page 4

EN

4

BURNER PORTS

Figure 4, Media Dam Placement

LAZY, YELLOW FLAMES

IDEAL

Figure 5, Burner Ports Location

Table 2, Factory Set Venturi Openings

Fuel

Center Burner Venturi

Side Burner Venturis

NG

1/8 in (3 mm)

1/8 in (3 mm)

F.  Test Inlet Pressure

IMPORTANT: For a proper pressure reading, apply the gas 
supply pressure tests with all other gas appliances on or at 
full capacity in the household.

Step 1: Loosen the inlet (IN) pressure tap screw 

(counterclockwise) on the gas valve.

Step 2: Attach a manometer to the inlet pressure tap with a ¼ 

in (6mm) ID hose. 

Step 3: Light the pilot and burner. Verify manometer reading 

is between the recommended minimum and maximum 
pressure settings. See Table 3.

Step 4: Turn off pilot and burner. 
Step 5: Disconnect hose and tighten the inlet pressure tap 

screw (clockwise). The screw should be snug; do not 
over tighten.

Step 6: Relight the pilot and burner.
Step 7: Reattach the manometer to the inlet pressure tap to 

verify tap is completely sealed. Manometer should read 
no pressure.

Table 3, Inlet Gas Supply Pressures

Fuel

Minimum

Maximum

NG

5” WC (1.25 kPa)

10.5” (2.62 kPa)

G.  Test Manifold Pressures

Step 1: Loosen the manifold (OUT) pressure tap screw 

(counterclockwise) on the gas valve.

Step 2: Attach a manometer to the outlet pressure tap with a ¼ 

in (6mm) ID hose. 

Step 3: Light the pilot and burner. Verify manometer reading 

is between the recommended low and high pressure 
settings. See Table 4.

Step 4: Turn off pilot and burner.
Step 5: Disconnect hose and tighten the outlet pressure tap 

screw (clockwise). The screw should be snug; do not 
over tighten.

Step 6: Relight the pilot and burner. 

Step 7: Reattach the manometer to the outlet pressure tap to 

verify tap is completely sealed. Manometer should read 
no pressure. 

Table 4, Manifold Gas Supply Pressures

Fuel

Low

High

NG

1.1” WC (.27 kPa)

3.8” WC (.85 kPa)

H.  Verify Operation

Step 1: Light the pilot. Visually check the pilot flame to verify 

flame envelopes the top of the flame sensor and extends 
far enough onto the burner for proper ignition. 

Step 2: To adjust the pilot flame, turn the pilot adjustment screw 

on the gas valve clockwise to decrease flame, and 
counterclockwise to increase flame. 

Step 3: Turn the appliance off. 
Step 4: Affix the gas type sticker on or near the gas valve.
Step 5: Reinstall the glass frame assembly and safety barrier.
Step 6: Light the pilot and burner. Visually check the main burner 

flame appearance for proper ignition and operation 
of the fireplace. Refer to the installation manual for 
complete adjustment procedures. 

Step 7: Complete and affix the ‘Gas Conversion’ labels as close 

to the rating plate as possible.

Step 8: Verify the input rating of the converted appliance. See 

Table 5.

Table 5, Input Ratings

Fuel

Minimum Input

Input

NG

15,000 Btu/h (4.4 kW)

42,000 Btu/h (12.3 kW)

GLASS 

MEDIA DAM

BURNER COVER/MEDIA TRAY

GLASS MEDIA

SIDE VIEW

Figure 6, Correct Burner and Pilot Flame Appearance

Summary of Contents for NCK-SL42-SPB

Page 1: ...RMÉMENT AUX EXIGENCES DU FABRICANT ET DES AUTORITÉS PROVINCIALES OU TERRITORIALES AYANT JURIDICTION ET AUX EXIGENCES DES CODES D INSTALLATION CAN CGA B149 1 OU CAN CGA B149 2 READ ALL STEPS BEFORE STARTING INSTALLATION LEAVE THESE INSTRUCTIONS WITH THE APPLIANCE This gas conversion kit installation instructions must be used in conjunction with the installation and operation manual provided with th...

Page 2: ......

Page 3: ...rner tube from its mounting cradles Step 3 Remove existing orifice caps Step 4 Replace with the orifice caps included with this kit Tighten caps securely The sizes are stamped on the orifices Table 1 Burner Orifice Sizes at Elevations 0 4 500 ft 1 372 m Fuel Center Burner Side Burners NG 37 DMS 54 DMS Figure 1 Burner Orifice BURNER ORIFICE C Convert Pilot Assembly Step 1 Using a 7 16 wrench loosen...

Page 4: ...ng is between the recommended low and high pressure settings See Table 4 Step 4 Turn off pilot and burner Step 5 Disconnect hose and tighten the outlet pressure tap screw clockwise The screw should be snug do not over tighten Step 6 Relight the pilot and burner Step 7 Reattach the manometer to the outlet pressure tap to verify tap is completely sealed Manometer should read no pressure Table 4 Mani...

Page 5: ... brûleur latéraux des supports de fixation Étape 2 Retirer le tube de brûleur central de ses supports de fixation Étape 3 Remplacez le par le nouvel orifice de brûleur fourni avec le kit numéro marqué sur l orifice du brûleur en veillant à bien serrer l orifice du brûleur Tableau 1 Dimension d orifice du brûleur Élévation 0 4500 pi 1372m Combustible Central Latéraux NG 37 DMS 54 DMS ORIFICE DU BRÛ...

Page 6: ... doit être vissée juste assez ne la vissez pas trop serrée Étape 6 Rallumez la veilleuse et le brûleur Étape 7 Branchez le manomètre au raccord de test de pression du manifold pour vérifier qu il est étanche Le manomètre ne devrait indiquer aucune pression lorsque la veilleuse et le brûleur sont allumés Tableau 4 Pression de gaz au manifold Combustible Minimum Low Maximum High NG 1 1 po WC 0 27 kP...