background image

#LCK-SP41L-D

R.1

3

HUSSONG MFG. CO., INC.

 KOZY HEAT FIREPLACES

EN

Conversion Kit Components

(1) Gas Conversion Label
(1) 50% Turndown Stepper Motor*
(1) Gas Label
(1) Pilot Injector - Propane: #.012LP
(1) Burner Orifice - Propane: 1.55mm

*Not included in the appliance parts package. Contact your local dealer for more 
information.

High Altitude Conversions

For high altitude installations in the United States, refer to the 

American Gas Association guidelines for the gas designed appliances 

derating method. For elevations above 2,000’ (610m), input ratings are 

to be reduced by 4% for each 1,000’ (305m) above sea level. 
When the appliance is installed at elevations above 4,500’ (1,372m), 

the certified high altitude rating shall be reduced at the rate of 4% for 

each additional 1,000’ (305m). Refer also to CSA-B149.1 Natural Gas 

and Propane Installation Code, local authorities, or codes which have 

jurisdiction in your area regarding the derate guidelines.

CAUTION: The gas supply shall be shut off prior to disconnecting the 

electrical power, before proceeding with the conversion.

A.  Prepare the Fireplace

Step 1:  Remove the safety barrier and glass frame assembly.
Step 2:  Remove log set, lava rock, and panel set (if installed).
Step 3:  Remove pilot shield.
Step 4:  Remove the front and back log plates. 
Step 5:  Remove the burner heat shield

Refer to the installation manual for more information.

B.  Replace Burner Orifice

Step 1:  Remove the existing burner orifice. See 

FIGURE 1.

Step 2:  Replace with the orifice cap included with this kit. Tighten cap 

securely. The size are stamped on the orifices.

Table 1, Burner Orifice Size at Elevations 0-4,500’ (1,372m)

Fuel

Orifice Size

Propane

1.55mm (DMS)

C.  Convert Pilot Assembly

Step 1:  Remove (2) screws securing the pilot assembly to the pilot 

bracket.

Step 2:  Place a 

7/16

” wrench on the upper fitting and 1/2” wrench 

on the lower fitting, and loosen the pilot hood by turning 

counterclockwise. 

Step 3:  Remove the pilot hood and existing pilot orifice inside the 

lower fitting.

Step 4:  Install new pilot orifice included with the kit (number stamped 

on pilot orifices) into the lower fitting.

Step 5:  Reattach pilot hood and tighten using 

7/16

” wrench on the 

upper fitting and 1/2” wrench on the lower fitting. Fitting should 

be snug. DO NOT OVER-TIGHTEN! 

Step 6:  Verify the pilot hood is positioned as shown in 

FIGURE 2

. Finally 

alignment of flame sensor and hood outlet is critical for proper 

ignition. 

Step 7:  Attach pilot assembly to pilot bracket with screws previously 

removed. 

Flame sensor

Hood outlet

Remove existing

pilot orifice and

replace with one

included in kit

Upper fitting

Pilot bracket

Lower fitting

Burner orifice

FIGURE 1, 

Location of Burner Orifices

FIGURE 2, 

Converted Pilot and Pilot Injectors

Summary of Contents for LCK-SP41L-D

Page 1: ...HTHE APPLIANCE This gas conversion kit installation instructions must be used in conjunction with the installation and operation manual provided with the appliance Please read the appliance owner s ma...

Page 2: ......

Page 3: ...ack log plates Step 5 Remove the burner heat shield Refer to the installation manual for more information B Replace Burner Orifice Step 1 Remove the existing burner orifice See FIGURE 1 Step 2 Replace...

Page 4: ...he screw securing the venturi cap and adjust to the correct setting See FIGURE 5 and TABLE 2 Regardless of venturi orientation closing the air shutter will achieve a desired yellow flame but may produ...

Page 5: ...rew clockwise The screw should be snug do not over tighten Step 6 Relight the pilot and burner Step 7 Reattach the manometer to the outlet pressure tap to verify tap is completely sealed Manometer sho...

Page 6: ...d information consulter le manuel d installation B Remplacement l orifice du br leur tape 1 Retirez l orifice du br leur existant Voir FIGURE 1 tape 2 Remplacez le par le nouvel orifice de br leur fou...

Page 7: ...obturateur d air du venturi et ajustez le au r glage appropri Voir FIGURE 5 et TABLEAU 2 R duire l ouverture de l obturateur d air du venturi avant ou arri re donnera la couleur de flamme jaune d sir...

Page 8: ...du raccord de test de pression de sortie sens horaire La vis doit tre viss e juste assez ne la serrez pas trop tape 6 Rallumez la veilleuse et le br leur tape 7 Rebranchez le manom tre au raccord de t...

Reviews: