4.1.2 Wiring the KPV to the Appliance
NOTE: Use Figure 4.7 and Figure 4.8 as wiring schematic references
when following the individual instructions below.
1. Find the hole in either side of the fireplace for access to Power
Vent wiring. See the top picture of Figure 4.4. The power vent
wire harness hole is located on a removable plate. Remove
screws that attach this plate to the outer shell for easier access.
Reattach the plate when finished. Run the loose wiring through
the larger section of the opening until you reach the start of the
flexible conduit. Unscrew the nut from the conduit end and slide
the conduit end into the smaller section of this opening. Screw
the locking nut back on the threads of the conduit securing it to
the fireplace. See the bottom picture of Figure 4.4
2. The power vent wire harness has the black hot wire split with
two female quick connections on either end. Plugs these into the
black leads that have quick connections coming off the control
module in the X12 combustion blower location. See Figure 4.5.
3. Locate the blue looped wire on the control module wire harness
that connects to the IPI/CPI location on the control module. Cut
this looped wires so you have two individual blue wires.
4. Locate the yellow looped "APS" wire on the control module wire
harness. Cut this looped wire for two individual yellow wires.
Strip back approximately 1/2" of the end of each wire. Using the
(2) provided blue wire nuts, twist one of the yellow APS wires
into the black wire coming from the vacuum switch in the power
vent assembly. Use the second blue wire nut to twist the second
yellow APS wire to the red wire coming from the vacuum switch
as shown in Figure 4.6.
5. Run the other end of the power vent wiring to the power vent
termination assembly. For attaching the wire harness to the fan
and vacuum switch, refer to Section 3.5 on page 11.
Figure 4.4, CLW-72 Power Vent Wire Harness Hole Location
Figure 4.5, Quick Connections to Black Leads
Figure 4.6, APS Wire Nuts
POWER VENT WIRE HARNESS HOLE LOCATION